[{"data":1,"prerenderedAt":2847},["ShallowReactive",2],{"help-guide-nl-elektrische-symbolen-plaatsen-en-verbinden":3,"help-alternates-place-and-connect-symbols":186,"help-related-nl":772},{"id":4,"title":5,"body":6,"category":164,"description":165,"extension":166,"guideId":167,"locale":168,"meta":169,"navigation":170,"order":171,"path":172,"publishedAt":173,"readTime":174,"seo":175,"slug":176,"stem":177,"tags":178,"updatedAt":173,"__hash__":185},"help\u002Fhelp\u002Fplace-and-connect-symbols.nl.md","Elektrische symbolen plaatsen en verbinden",{"type":7,"value":8,"toc":156},"minimark",[9,18,24,29,36,52,55,59,69,80,83,88,92,95,98,101,127,130,134,148],[10,11,12,13,17],"p",{},"Een symbool in het grondplan beschrijft eerst zijn ",[14,15,16],"strong",{},"fysieke plaats",". Pas de koppeling met de elektrische topologie maakt er een toegewezen verbruiker of toestel van voor stroomkring, schema en documenten.",[10,19,20],{},[21,22],"a",{"id":23},"place",[25,26,28],"h2",{"id":27},"symbolen-uit-het-palet-plaatsen","Symbolen uit het palet plaatsen",[10,30,31,32,35],{},"Open in ",[14,33,34],{},"Grondplan"," het gereedschapspalet en kies bijvoorbeeld een stopcontact, schakelaar, lichtpunt, vast toestel, doos of verdeelkast. De gereedschapsiconen staan in het palet; bij aanwijzen toont de toepassing de naam.",[37,38,39,43,46,49],"ol",{},[40,41,42],"li",{},"Kies het gereedschap voor het symbool.",[40,44,45],{},"Plaats wandgebonden toestellen aan de juiste kant van de muur. Stopcontacten en schakelaars klikken op de muur vast.",[40,47,48],{},"Plaats vrije lichtpunten of spots in de ruimte.",[40,50,51],{},"Controleer na het plaatsen positie, oriëntatie en symboolvariant.",[10,53,54],{},"Een symbool kan alleen worden geplaatst waar de editor een geldige positie herkent. De preview toont vóór het bevestigen de echte geometrie. Corrigeer eerst muur of ruimte wanneer het symbool niet op de beoogde plaats vastklikt.",[25,56,58],{"id":57},"gemeenschappelijke-afdekramen-maken","Gemeenschappelijke afdekramen maken",[10,60,61,62,65,66,68],{},"Een installatiegroep is een fysieke combinatie met een gemeenschappelijk twee- tot vijfvoudig afdekraam. Zij is ",[14,63,64],{},"geen"," schakelketen en ",[14,67,64],{}," stroomkring.",[10,70,71,72,75,76,79],{},"Sleep geschikte toestellen aan dezelfde muurzijde bij elkaar of start het raamgereedschap. In het paneel ",[14,73,74],{},"Installatiegroep"," kiest u horizontaal of verticaal en sluit u af met ",[14,77,78],{},"Gereed",". Verplaatst u één lid, dan verplaatst de combinatie mee.",[10,81,82],{},"Schakelaars, standaardstopcontacten, Ethernet- en coax-aansluitingen kunnen worden gegroepeerd. IP44-stopcontacten blijven vanwege hun afdichtende raam uitgesloten. Passieve data-aansluitingen worden hierdoor geen 230-V-verbruikers.",[10,84,85],{},[21,86],{"id":87},"topology",[25,89,91],{"id":90},"met-de-elektrische-topologie-verbinden","Met de elektrische topologie verbinden",[10,93,94],{},"Open de eigenschappen van het geplaatste toestel en koppel het aan een typecompatibele knoop in de elektrische topologie. Varianten van stopcontacten, schakelaars en lichtpunten worden als passende families behandeld. Verbindings- en aftakdozen zijn alleen elektrisch werkzaam wanneer ze werkelijk gekoppeld zijn.",[10,96,97],{},"Controleer daarna de lijst met niet-verbonden onderdelen. Daarin staan symbolen die wel in het grondplan liggen, maar nog niet bij het elektrische model horen.",[10,99,100],{},"Houd dit onderscheid aan:",[102,103,104,110,115,121],"ul",{},[40,105,106,109],{},[14,107,108],{},"Positie",": waar bevindt het toestel zich?",[40,111,112,114],{},[14,113,74],{},": welke inzetten delen een afdekraam?",[40,116,117,120],{},[14,118,119],{},"Topologie",": welke elektrische knoop hoort bij het toestel?",[40,122,123,126],{},[14,124,125],{},"Stroomkring",": via welk beveiligingstoestel wordt die knoop gevoed?",[10,128,129],{},"Een verandering aan het afdekraam verandert geen schakelfunctie of stroomkring. Voor de bediening van verlichting bewerkt u daarna de schakelketen; voor de voeding wijst u toestellen aan een stroomkring toe.",[25,131,133],{"id":132},"controle-vóór-de-volgende-stap","Controle vóór de volgende stap",[102,135,136,139,142,145],{},[40,137,138],{},"Elk symbool staat op de werkelijk bedoelde plaats.",[40,140,141],{},"Wandgebonden toestellen zijn aan de juiste muurzijde uitgelijnd.",[40,143,144],{},"Raamcombinaties volgen de geplande montage, niet een veronderstelde bedrading.",[40,146,147],{},"Alle elektrische toestellen zijn met de passende topologieknoop gekoppeld.",[10,149,150,151,155],{},"Volgende stap: ",[21,152,154],{"href":153},"\u002Fhelp\u002Fschakelketens-stroomkringen-en-kabelroutes","schakelketens, stroomkringen en kabelroutes bewerken",".",{"title":157,"searchDepth":158,"depth":158,"links":159},"",2,[160,161,162,163],{"id":27,"depth":158,"text":28},{"id":57,"depth":158,"text":58},{"id":90,"depth":158,"text":91},{"id":132,"depth":158,"text":133},"getting_started","Plaats toestellen op de juiste positie, vorm gemeenschappelijke afdekramen en verbind elektrische symbolen met de passende topologie.","md","place-and-connect-symbols","nl",{},true,6,"\u002Fhelp\u002Fplace-and-connect-symbols.nl","2026-08-21","8 min",{"title":5,"description":165},"elektrische-symbolen-plaatsen-en-verbinden","help\u002Fplace-and-connect-symbols.nl",[179,180,181,182,183,184],"elektrische symbolen","stopcontacten","schakelaars","verlichting","afdekramen","topologie","Nn5qNlCBUOQPo7aQ1I-pN7iR7m9qQOsocrx8VDKYCEs",[187,350,511,670],{"id":188,"title":189,"body":190,"category":164,"description":335,"extension":166,"guideId":167,"locale":336,"meta":337,"navigation":170,"order":171,"path":338,"publishedAt":173,"readTime":339,"seo":340,"slug":341,"stem":342,"tags":343,"updatedAt":173,"__hash__":349},"help\u002Fhelp\u002Fplace-and-connect-symbols.de.md","Elektrosymbole platzieren und mit der Topologie verbinden",{"type":7,"value":191,"toc":329},[192,199,203,207,214,228,231,235,246,257,260,264,268,271,274,277,301,304,308,322],[10,193,194,195,198],{},"Ein Symbol im Grundriss beschreibt zuerst seinen ",[14,196,197],{},"physischen Ort",". Erst die Verknüpfung mit der elektrischen Topologie macht daraus einen zugeordneten Verbraucher oder ein zugeordnetes Betriebsmittel für Stromkreis, Schema und Dokumente.",[10,200,201],{},[21,202],{"id":23},[25,204,206],{"id":205},"symbole-aus-der-palette-platzieren","Symbole aus der Palette platzieren",[10,208,209,210,213],{},"Öffnen Sie im Bereich ",[14,211,212],{},"Grundriss"," die Werkzeugpalette und wählen Sie das gewünschte Werkzeug, zum Beispiel Steckdose, Schalter, Leuchte, Festanschluss, Dose oder Verteiler. Die Werkzeug-Icons stehen direkt in der Palette; beim Überfahren zeigt die Anwendung die Bezeichnung.",[37,215,216,219,222,225],{},[40,217,218],{},"Wählen Sie das Symbolwerkzeug.",[40,220,221],{},"Platzieren Sie wandgebundene Geräte auf der richtigen Wandseite. Steckdosen und Schalter rasten an Wänden ein.",[40,223,224],{},"Platzieren Sie freie Leuchten oder Spots im Raum.",[40,226,227],{},"Prüfen Sie nach dem Setzen Position, Ausrichtung und Symbolvariante.",[10,229,230],{},"Ein Symbol kann nur dort gesetzt werden, wo der Editor eine gültige Position erkennt. Die Vorschau zeigt vor dem Abschluss die tatsächliche Geometrie. Korrigieren Sie Wand und Raum zuerst, wenn ein Symbol nicht an der vorgesehenen Stelle einrastet.",[25,232,234],{"id":233},"gemeinsame-abdeckrahmen-bilden","Gemeinsame Abdeckrahmen bilden",[10,236,237,238,241,242,245],{},"Eine Installationsgruppe bildet eine physische Kombination mit gemeinsamem zwei- bis fünffachem Abdeckrahmen. Sie ist ",[14,239,240],{},"keine"," Schalterkette und ",[14,243,244],{},"kein"," Stromkreis.",[10,247,248,249,252,253,256],{},"Ziehen Sie geeignete Geräte auf derselben Wandseite zusammen oder starten Sie das Rahmenwerkzeug. Im Panel ",[14,250,251],{},"Installationsgruppe"," wählen Sie horizontal oder vertikal und schließen mit ",[14,254,255],{},"Fertig"," ab. Beim Verschieben eines Mitglieds bewegt sich die Kombination zusammen.",[10,258,259],{},"Gruppierbar sind Schalter, Standardsteckdosen sowie Ethernet- und Koax-Anschlüsse. IP44-Steckdosen bleiben wegen ihres gedichteten Rahmens außerhalb dieser Gruppierung. Passive Datenanschlüsse werden dadurch nicht zu 230-V-Verbrauchern.",[10,261,262],{},[21,263],{"id":87},[25,265,267],{"id":266},"mit-der-elektrischen-topologie-verknüpfen","Mit der elektrischen Topologie verknüpfen",[10,269,270],{},"Öffnen Sie die Eigenschaften des platzierten Geräts und verknüpfen Sie es mit einem typkompatiblen Knoten der elektrischen Topologie. Steckdosen-, Schalter- und Lichtvarianten werden dabei jeweils als passende Familie behandelt. Verbindungs- und Abzweigdosen bleiben nur dann elektrisch wirksam, wenn sie tatsächlich verknüpft sind.",[10,272,273],{},"Prüfen Sie anschließend die Liste der unverbundenen Komponenten. Sie zeigt Symbole, die zwar im Grundriss liegen, aber noch nicht zum elektrischen Modell gehören.",[10,275,276],{},"Wichtig ist die Reihenfolge der Begriffe:",[102,278,279,285,290,295],{},[40,280,281,284],{},[14,282,283],{},"Position",": Wo befindet sich das Gerät im Grundriss?",[40,286,287,289],{},[14,288,251],{},": Welche Einsätze teilen sich einen Abdeckrahmen?",[40,291,292,294],{},[14,293,119],{},": Welcher elektrische Knoten gehört zu diesem Gerät?",[40,296,297,300],{},[14,298,299],{},"Stromkreis",": Über welches Schutzorgan wird der Knoten versorgt?",[10,302,303],{},"Eine Änderung am Abdeckrahmen ändert weder die Schaltfunktion noch die Stromkreiszuordnung. Für die Bedienung von Leuchten bearbeiten Sie anschließend die Schalterkette; für die elektrische Versorgung ordnen Sie die Geräte einem Stromkreis zu.",[25,305,307],{"id":306},"vor-dem-weiterarbeiten-prüfen","Vor dem Weiterarbeiten prüfen",[102,309,310,313,316,319],{},[40,311,312],{},"Jedes Symbol steht an der realen vorgesehenen Stelle.",[40,314,315],{},"Wandgebundene Geräte sind an der richtigen Wandseite ausgerichtet.",[40,317,318],{},"Rahmenkombinationen entsprechen der geplanten Montage, nicht einer angenommenen Verdrahtung.",[40,320,321],{},"Alle elektrischen Geräte sind mit dem passenden Topologieknoten verknüpft.",[10,323,324,325,155],{},"Als Nächstes: ",[21,326,328],{"href":327},"\u002Fde\u002Fhelp\u002Fschalterketten-stromkreise-und-kabelwege","Schalterketten, Stromkreise und Kabelwege bearbeiten",{"title":157,"searchDepth":158,"depth":158,"links":330},[331,332,333,334],{"id":205,"depth":158,"text":206},{"id":233,"depth":158,"text":234},{"id":266,"depth":158,"text":267},{"id":306,"depth":158,"text":307},"Setzen Sie Geräte am richtigen Ort, bilden Sie gemeinsame Abdeckrahmen und verbinden Sie elektrische Symbole mit der passenden Topologie.","de",{},"\u002Fhelp\u002Fplace-and-connect-symbols.de","8 Min.",{"title":189,"description":335},"elektrosymbole-platzieren-und-verbinden","help\u002Fplace-and-connect-symbols.de",[344,345,346,347,348,119],"Elektrosymbole","Steckdosen","Schalter","Leuchten","Abdeckrahmen","04Gof6i0PgLxh5v57EZU6zYri7EqUXSo6BEWmafjTSM",{"id":351,"title":352,"body":353,"category":164,"description":497,"extension":166,"guideId":167,"locale":498,"meta":499,"navigation":170,"order":171,"path":500,"publishedAt":173,"readTime":174,"seo":501,"slug":502,"stem":503,"tags":504,"updatedAt":173,"__hash__":510},"help\u002Fhelp\u002Fplace-and-connect-symbols.en.md","Place and connect electrical symbols",{"type":7,"value":354,"toc":491},[355,362,366,370,377,391,394,398,408,419,422,426,430,433,436,439,463,466,470,484],[10,356,357,358,361],{},"A symbol on the floor plan first describes its ",[14,359,360],{},"physical location",". Linking it to the electrical topology turns it into an assigned consumer or item of equipment for a circuit, diagram and documents.",[10,363,364],{},[21,365],{"id":23},[25,367,369],{"id":368},"place-symbols-from-the-palette","Place symbols from the palette",[10,371,372,373,376],{},"In ",[14,374,375],{},"Floor plan",", open the tool palette and select a socket, switch, light, fixed appliance, box or distribution board. The tool icons are shown in the palette; pointing at one shows its name.",[37,378,379,382,385,388],{},[40,380,381],{},"Select the symbol tool.",[40,383,384],{},"Place wall-mounted devices on the correct side of the wall. Sockets and switches snap to walls.",[40,386,387],{},"Place free lights or spots in the room.",[40,389,390],{},"Check the position, orientation and symbol variant after placing it.",[10,392,393],{},"A symbol can only be placed where the editor identifies a valid location. The preview shows the final geometry before you commit it. Correct the wall or room first if a symbol will not snap where you intend.",[25,395,397],{"id":396},"create-shared-cover-frames","Create shared cover frames",[10,399,400,401,404,405,407],{},"An installation group is a physical combination with a shared two- to five-gang cover frame. It is ",[14,402,403],{},"not"," a switch chain and ",[14,406,403],{}," a circuit.",[10,409,410,411,414,415,418],{},"Drag suitable devices together on the same wall side, or start the cover-frame tool. In the ",[14,412,413],{},"Installation group"," panel, choose horizontal or vertical and complete it with ",[14,416,417],{},"Done",". Moving one member moves the combination.",[10,420,421],{},"Switches, standard sockets, Ethernet and coax outlets can be grouped. IP44 sockets remain excluded because they use a sealed frame. Passive data outlets do not become 230 V consumers as a result.",[10,423,424],{},[21,425],{"id":87},[25,427,429],{"id":428},"link-the-device-to-electrical-topology","Link the device to electrical topology",[10,431,432],{},"Open the placed device's properties and link it to a type-compatible node in the electrical topology. Socket, switch and light variants are treated as matching families. Connection and junction boxes only become electrically effective when they are genuinely linked.",[10,434,435],{},"Then review the list of unconnected components. It shows symbols that are located on the floor plan but are not yet part of the electrical model.",[10,437,438],{},"Keep these concepts separate:",[102,440,441,446,451,457],{},[40,442,443,445],{},[14,444,283],{},": where is the device on the floor plan?",[40,447,448,450],{},[14,449,413],{},": which inserts share one cover frame?",[40,452,453,456],{},[14,454,455],{},"Topology",": which electrical node belongs to the device?",[40,458,459,462],{},[14,460,461],{},"Circuit",": which protective device supplies that node?",[10,464,465],{},"Changing a cover frame changes neither a switching function nor a circuit assignment. Next, edit the switch chain for lighting control and assign devices to a circuit for electrical supply.",[25,467,469],{"id":468},"check-before-continuing","Check before continuing",[102,471,472,475,478,481],{},[40,473,474],{},"Every symbol is in its intended real-world location.",[40,476,477],{},"Wall-mounted devices are aligned to the right wall side.",[40,479,480],{},"Cover-frame combinations represent the intended mounting, not assumed wiring.",[40,482,483],{},"All electrical devices are linked to the appropriate topology node.",[10,485,486,487,155],{},"Next: ",[21,488,490],{"href":489},"\u002Fen\u002Fhelp\u002Fswitch-chains-circuits-and-cable-routes","edit switch chains, circuits and cable routes",{"title":157,"searchDepth":158,"depth":158,"links":492},[493,494,495,496],{"id":368,"depth":158,"text":369},{"id":396,"depth":158,"text":397},{"id":428,"depth":158,"text":429},{"id":468,"depth":158,"text":469},"Place devices at the right location, create shared cover frames and connect electrical symbols to the appropriate topology.","en",{},"\u002Fhelp\u002Fplace-and-connect-symbols.en",{"title":352,"description":497},"place-and-connect-electrical-symbols","help\u002Fplace-and-connect-symbols.en",[505,506,507,508,509,87],"electrical symbols","sockets","switches","lights","cover frames","pKq3YFepVen1i8o4BElksAYt-OeKD7QcZs5DZ4o6Svo",{"id":512,"title":513,"body":514,"category":164,"description":656,"extension":166,"guideId":167,"locale":657,"meta":658,"navigation":170,"order":171,"path":659,"publishedAt":173,"readTime":174,"seo":660,"slug":661,"stem":662,"tags":663,"updatedAt":173,"__hash__":669},"help\u002Fhelp\u002Fplace-and-connect-symbols.fr.md","Placer et relier des symboles électriques",{"type":7,"value":515,"toc":650},[516,523,527,531,538,552,555,559,569,580,583,587,591,594,597,600,622,625,629,643],[10,517,518,519,522],{},"Un symbole sur le plan décrit d’abord son ",[14,520,521],{},"emplacement physique",". Le lien avec la topologie électrique en fait ensuite un récepteur ou équipement attribué à un circuit, un schéma et des documents.",[10,524,525],{},[21,526],{"id":23},[25,528,530],{"id":529},"placer-les-symboles-depuis-la-palette","Placer les symboles depuis la palette",[10,532,533,534,537],{},"Dans ",[14,535,536],{},"Plan",", ouvrez la palette d’outils et choisissez une prise, un interrupteur, un luminaire, un appareil fixe, une boîte ou un tableau. Les icônes d’outil sont affichées dans la palette ; leur libellé apparaît au survol.",[37,539,540,543,546,549],{},[40,541,542],{},"Sélectionnez l’outil du symbole.",[40,544,545],{},"Placez les appareils muraux du bon côté du mur. Les prises et interrupteurs s’aimantent aux murs.",[40,547,548],{},"Placez les luminaires ou spots libres dans la pièce.",[40,550,551],{},"Vérifiez position, orientation et variante de symbole après la pose.",[10,553,554],{},"Un symbole ne peut être posé qu’à un emplacement que l’éditeur reconnaît comme valide. L’aperçu montre la géométrie finale avant validation. Corrigez d’abord mur ou pièce si le symbole ne s’aimante pas à l’endroit prévu.",[25,556,558],{"id":557},"créer-des-cadres-communs","Créer des cadres communs",[10,560,561,562,565,566,568],{},"Un groupe d’installation est une combinaison physique avec un cadre commun de deux à cinq postes. Ce n’est ",[14,563,564],{},"ni"," une chaîne de commande ",[14,567,564],{}," un circuit.",[10,570,571,572,575,576,579],{},"Glissez des appareils compatibles ensemble sur le même côté d’un mur ou démarrez l’outil de cadre. Dans le panneau ",[14,573,574],{},"Groupe d’installation",", choisissez horizontal ou vertical et terminez avec ",[14,577,578],{},"Terminer",". Déplacer un membre déplace la combinaison.",[10,581,582],{},"Interrupteurs, prises standard, prises Ethernet et coaxiales peuvent être groupés. Les prises IP44 restent exclues à cause de leur cadre étanche. Les prises de données passives ne deviennent pas pour autant des récepteurs 230 V.",[10,584,585],{},[21,586],{"id":87},[25,588,590],{"id":589},"relier-lappareil-à-la-topologie-électrique","Relier l’appareil à la topologie électrique",[10,592,593],{},"Ouvrez les propriétés de l’appareil placé et reliez-le à un nœud compatible de la topologie électrique. Les variantes de prise, interrupteur et luminaire sont traitées comme des familles compatibles. Les boîtes de connexion et de dérivation ne deviennent électriquement effectives que lorsqu’elles sont réellement reliées.",[10,595,596],{},"Contrôlez ensuite la liste des composants non reliés. Elle affiche les symboles présents sur le plan mais qui ne font pas encore partie du modèle électrique.",[10,598,599],{},"Conservez cette distinction :",[102,601,602,607,612,617],{},[40,603,604,606],{},[14,605,283],{}," : où se trouve l’appareil sur le plan ?",[40,608,609,611],{},[14,610,574],{}," : quels mécanismes partagent un cadre ?",[40,613,614,616],{},[14,615,119],{}," : quel nœud électrique appartient à l’appareil ?",[40,618,619,621],{},[14,620,461],{}," : quel appareil de protection alimente ce nœud ?",[10,623,624],{},"Modifier un cadre ne change ni la fonction de commande ni l’affectation à un circuit. Éditez ensuite la chaîne de commande pour l’éclairage et affectez les appareils à un circuit pour leur alimentation.",[25,626,628],{"id":627},"vérifier-avant-de-poursuivre","Vérifier avant de poursuivre",[102,630,631,634,637,640],{},[40,632,633],{},"Chaque symbole est à l’emplacement réel prévu.",[40,635,636],{},"Les appareils muraux sont alignés du bon côté du mur.",[40,638,639],{},"Les combinaisons de cadre correspondent au montage prévu, pas à un câblage supposé.",[40,641,642],{},"Tous les appareils électriques sont reliés au bon nœud de topologie.",[10,644,645,646,155],{},"Étape suivante : ",[21,647,649],{"href":648},"\u002Ffr\u002Fhelp\u002Fcommandes-circuits-et-chemins-de-cables","modifier les chaînes de commande, circuits et chemins de câbles",{"title":157,"searchDepth":158,"depth":158,"links":651},[652,653,654,655],{"id":529,"depth":158,"text":530},{"id":557,"depth":158,"text":558},{"id":589,"depth":158,"text":590},{"id":627,"depth":158,"text":628},"Placez les appareils au bon endroit, créez des cadres communs et reliez les symboles électriques à la topologie appropriée.","fr",{},"\u002Fhelp\u002Fplace-and-connect-symbols.fr",{"title":513,"description":656},"placer-et-relier-des-symboles-electriques","help\u002Fplace-and-connect-symbols.fr",[664,665,666,667,668,184],"symboles électriques","prises","interrupteurs","luminaires","cadres","_mbTFtbFidiat6hhTreMwaiZFU-W3m8ip5QtrgqQveM",{"id":4,"title":5,"body":671,"category":164,"description":165,"extension":166,"guideId":167,"locale":168,"meta":769,"navigation":170,"order":171,"path":172,"publishedAt":173,"readTime":174,"seo":770,"slug":176,"stem":177,"tags":771,"updatedAt":173,"__hash__":185},{"type":7,"value":672,"toc":763},[673,677,681,683,687,697,699,701,707,713,715,719,721,723,725,727,745,747,749,759],[10,674,12,675,17],{},[14,676,16],{},[10,678,679],{},[21,680],{"id":23},[25,682,28],{"id":27},[10,684,31,685,35],{},[14,686,34],{},[37,688,689,691,693,695],{},[40,690,42],{},[40,692,45],{},[40,694,48],{},[40,696,51],{},[10,698,54],{},[25,700,58],{"id":57},[10,702,61,703,65,705,68],{},[14,704,64],{},[14,706,64],{},[10,708,71,709,75,711,79],{},[14,710,74],{},[14,712,78],{},[10,714,82],{},[10,716,717],{},[21,718],{"id":87},[25,720,91],{"id":90},[10,722,94],{},[10,724,97],{},[10,726,100],{},[102,728,729,733,737,741],{},[40,730,731,109],{},[14,732,108],{},[40,734,735,114],{},[14,736,74],{},[40,738,739,120],{},[14,740,119],{},[40,742,743,126],{},[14,744,125],{},[10,746,129],{},[25,748,133],{"id":132},[102,750,751,753,755,757],{},[40,752,138],{},[40,754,141],{},[40,756,144],{},[40,758,147],{},[10,760,150,761,155],{},[21,762,154],{"href":153},{"title":157,"searchDepth":158,"depth":158,"links":764},[765,766,767,768],{"id":27,"depth":158,"text":28},{"id":57,"depth":158,"text":58},{"id":90,"depth":158,"text":91},{"id":132,"depth":158,"text":133},{},{"title":5,"description":165},[179,180,181,182,183,184],[773,1040,1306,1632,2431,2611,2713],{"id":774,"title":775,"body":776,"category":164,"description":1024,"extension":166,"guideId":1025,"locale":168,"meta":1026,"navigation":170,"order":1027,"path":1028,"publishedAt":1029,"readTime":174,"seo":1030,"slug":1031,"stem":1032,"tags":1033,"updatedAt":1029,"__hash__":1039},"help\u002Fhelp\u002Fgetting-started.nl.md","Aan de slag: van project tot eerste export",{"type":7,"value":777,"toc":1015},[778,781,787,792,796,803,806,823,826,834,838,848,851,854,857,871,876,880,883,886,889,896,904,908,911,914,931,934,939,943,946,949,952,960,964,970,973,981,985,988,1008],[10,779,780],{},"PlanElec gebruikt één projectmodel voor het grondplan, de elektrische topologie, de verdeelkast en de documenten. Daardoor werkt u het best in een vaste volgorde: eerst de ruimte en toestellen vastleggen, daarna de elektrische structuur controleren en pas dan exporteren.",[782,783,784],"blockquote",{},[10,785,786],{},"Gebruikt u PlanElec als eigenaar of bouwheer? Laat keuzes en documenten vóór uitvoering en keuring nakijken door een gekwalificeerde elektricien.",[10,788,789],{},[21,790],{"id":791},"project",[25,793,795],{"id":794},"_1-maak-het-project-aan","1. Maak het project aan",[10,797,798,799,802],{},"Kies in het projectoverzicht ",[14,800,801],{},"Project aanmaken",". U kunt starten met de begeleide workflow, een gelokaliseerde projecttemplate of een leeg project.",[10,804,805],{},"Vul minstens een herkenbare projectnaam in. In de projectgegevens kunt u later ook deze gegevens bewaren:",[102,807,808,811,814,817,820],{},[40,809,810],{},"klant en contactgegevens;",[40,812,813],{},"installatieadres;",[40,815,816],{},"installateur en eventueel logo;",[40,818,819],{},"EAN, installatie- en stroomtype;",[40,821,822],{},"erkend controleorganisme en projectnotities.",[10,824,825],{},"Deze gegevens worden hergebruikt in titelblokken, het zelfcontrolerapport en het werkdossier. Ontbrekende gegevens blokkeren uitproberen en conceptdownloads niet, maar controleer ze voordat u documenten deelt.",[10,827,828,831],{},[21,829],{"id":830},"floorplan",[21,832],{"id":833},"situation-plan",[25,835,837],{"id":836},"_2-teken-het-grondplan-en-bouw-het-situatieplan-op","2. Teken het grondplan en bouw het situatieplan op",[10,839,840,841,844,845,155],{},"Maak eerst een verdieping aan. Teken daarna de buiten- en binnenmuren met het veelhoek-, rechthoek- of lijnwerktuig. Gesloten wandvlakken worden als ruimtes herkend; geef elke ruimte een duidelijke naam, zoals ",[14,842,843],{},"Keuken"," of ",[14,846,847],{},"Slaapkamer 1",[10,849,850],{},"Hebt u al een plan als afbeelding, dan kunt u dat als referentie gebruiken. Kalibreer het met een bekende maat voordat u nauwkeurig plaatst. De afbeelding is een onderlegger: muren, openingen en elektrische punten blijven afzonderlijke projectgegevens.",[10,852,853],{},"Plaats vervolgens deuren, ramen, trappen en de elektrische symbolen op hun werkelijke locatie. Het resulterende grondplan vormt de basis van het situatieschema dat u later als PDF exporteert.",[10,855,856],{},"Praktische controle:",[37,858,859,862,865,868],{},[40,860,861],{},"Zijn alle verdiepingen en ruimtes aanwezig en benoemd?",[40,863,864],{},"Staan stopcontacten, schakelaars, lichtpunten en vaste toestellen in de juiste ruimte?",[40,866,867],{},"Is de verdeelkast op het plan geplaatst?",[40,869,870],{},"Zijn eventuele badkamerzones en bijzondere toestellen correct vastgelegd?",[10,872,873],{},[21,874],{"id":875},"devices",[25,877,879],{"id":878},"_3-plaats-en-verbind-elektrische-punten","3. Plaats en verbind elektrische punten",[10,881,882],{},"Open het symbolenpalet en plaats de nodige elektrische punten. Sommige hulpmiddelen kunnen voorstellen maken voor stopcontacten, verlichting, standaardtoestellen of een spotraster. Beoordeel en pas die voorstellen aan: ze vervangen uw keuze van aantallen en posities niet.",[10,884,885],{},"Koppel schakelaars en lichtpunten in schakelketens. Voor vrije schakelaars en lichten in een ruimte kan PlanElec een keten voorstellen; de volgorde blijft manueel aanpasbaar.",[10,887,888],{},"Een symbool op het grondplan en een elektrisch knooppunt horen bij elkaar, maar zijn niet hetzelfde. Controleer daarom onverbonden componenten. Zonder geldige topologie kan een toestel niet betrouwbaar in een stroomkring, kabel- of materiaallijst terechtkomen.",[10,890,891,892,155],{},"Meer over automatische voorstellen, kabels en stroomkringen leest u in ",[21,893,895],{"href":894},"\u002Fhelp\u002Fautomatische-planning","Automatische planning gebruiken",[10,897,898,901],{},[21,899],{"id":900},"automatic-planning",[21,902],{"id":903},"cabinet",[25,905,907],{"id":906},"_4-controleer-de-elektrische-topologie-en-verdeelkast","4. Controleer de elektrische topologie en verdeelkast",[10,909,910],{},"Gebruik de automatische stroomkringtoewijzing als startvoorstel. PlanElec groepeert standaardverbruikers, maakt voor bijzondere toestellen waar nodig een aparte beveiliging aan en kan lasten over fasen verdelen. Bekijk de preview voordat u de toewijzing toepast.",[10,912,913],{},"Open daarna de verdeelkasteditor. Automatisch vullen plaatst bestaande hoofdschakelaars, differentieelschakelaars en automaten op de DIN-rails en houdt ruimte vrij. Controleer vervolgens:",[102,915,916,919,922,925,928],{},[40,917,918],{},"de beveiligingsketen en de toegewezen verbruikers;",[40,920,921],{},"kabeltype, doorsnede en route;",[40,923,924],{},"RCD-groepen en aantallen stroomkringen;",[40,926,927],{},"faseverdeling bij een meerfasige installatie;",[40,929,930],{},"vrije moduleplaatsen en de werkelijke kastafmetingen.",[10,932,933],{},"Alle automatische resultaten blijven bewerkbaar. Een voorstel is geen ontwerpbeslissing of materiaalbestelling.",[10,935,936],{},[21,937],{"id":938},"schema",[25,940,942],{"id":941},"_5-bekijk-het-eendraadschema-en-de-zelfcontrole","5. Bekijk het eendraadschema en de zelfcontrole",[10,944,945],{},"Het eendraadschema wordt uit dezelfde elektrische topologie opgebouwd. Controleer circuitnamen, beveiligingen, kabelgegevens, verbindingen en symbolen. Los fouten en waarschuwingen op die PlanElec met de beschikbare projectgegevens kan herkennen.",[10,947,948],{},"De AREI\u002FRGIE-zelfcontrole ondersteunt een gedocumenteerd deel van de softwarematig controleerbare regels. Een foutloze run betekent alleen dat binnen die ondersteunde regels geen fout is gevonden. Metingen, omstandigheden ter plaatse en niet gemodelleerde regels vallen buiten deze controle.",[10,950,951],{},"PlanElec levert dus geen conformiteitsattest en vervangt geen officiële keuring door een erkend controleorganisme.",[10,953,954,957],{},[21,955],{"id":956},"export",[21,958],{"id":959},"exports",[25,961,963],{"id":962},"_6-exporteer-en-beoordeel-de-documenten","6. Exporteer en beoordeel de documenten",[10,965,372,966,969],{},[14,967,968],{},"Export"," kunt u onder andere het eendraadschema en het situatieschema als PDF genereren. Ook het zelfcontrolerapport en lijsten voor stroomkringen, kabels en materiaal zijn centraal beschikbaar; de gedetailleerde lijsten bevinden zich nog in de pilotworkflow.",[10,971,972],{},"U kunt geselecteerde documenten ook samenvoegen tot een werkdossier met voorblad, inhoudsoverzicht en doorlopende paginanummering. Bekijk vóór delen iedere pagina en controleer de projectmetadata.",[10,974,975,976,980],{},"Zie ",[21,977,979],{"href":978},"\u002Fhelp\u002Fdocumenten-exporteren","Documenten exporteren"," voor de volledige lijst, statussen en beperkingen.",[25,982,984],{"id":983},"een-bruikbare-eerste-mijlpaal","Een bruikbare eerste mijlpaal",[10,986,987],{},"Uw eerste project is goed opgebouwd wanneer:",[102,989,990,993,996,999,1002,1005],{},[40,991,992],{},"ruimtes en elektrische punten op het situatieplan staan;",[40,994,995],{},"alle relevante punten met de elektrische topologie verbonden zijn;",[40,997,998],{},"stroomkringen, kabels en kastindeling zijn beoordeeld;",[40,1000,1001],{},"het eendraadschema leesbaar is;",[40,1003,1004],{},"de zelfcontrole is uitgevoerd en resterende bevindingen begrepen zijn;",[40,1006,1007],{},"geëxporteerde documenten visueel en inhoudelijk zijn nagekeken.",[10,1009,1010,1011,155],{},"Wilt u meteen beginnen? ",[21,1012,1014],{"href":1013},"\u002Fauth\u002Fregister","Maak gratis een Early Access-account aan",{"title":157,"searchDepth":158,"depth":158,"links":1016},[1017,1018,1019,1020,1021,1022,1023],{"id":794,"depth":158,"text":795},{"id":836,"depth":158,"text":837},{"id":878,"depth":158,"text":879},{"id":906,"depth":158,"text":907},{"id":941,"depth":158,"text":942},{"id":962,"depth":158,"text":963},{"id":983,"depth":158,"text":984},"Bouw stap voor stap een PlanElec-project op: projectgegevens, grondplan, ruimtes, elektrische punten, verdeelkast, schema en export.","getting-started",{},1,"\u002Fhelp\u002Fgetting-started.nl","2026-07-20",{"title":775,"description":1024},"aan-de-slag","help\u002Fgetting-started.nl",[791,1034,1035,1036,1037,1038,956],"grondplan","situatieplan","verbruikers","verdeelkast","eendraadschema","y0YexoIxq6iYFBoXVtIjfQB52kgGtd0zn6eLhTijPD8",{"id":1041,"title":1042,"body":1043,"category":1291,"description":1292,"extension":166,"guideId":900,"locale":168,"meta":1293,"navigation":170,"order":158,"path":1294,"publishedAt":1029,"readTime":1295,"seo":1296,"slug":1297,"stem":1298,"tags":1299,"updatedAt":1029,"__hash__":1305},"help\u002Fhelp\u002Fautomatic-planning.nl.md","Automatische planning gebruiken en controleren",{"type":7,"value":1044,"toc":1280},[1045,1048,1054,1063,1067,1070,1073,1090,1093,1098,1101,1104,1109,1113,1116,1119,1122,1136,1139,1144,1148,1151,1171,1174,1179,1183,1186,1189,1193,1197,1200,1203,1217,1220,1227,1231,1234,1272,1275],[10,1046,1047],{},"De automatische functies van PlanElec zijn bedoeld als bewerkbare voorstellen. Ze nemen repetitief werk over, maar kunnen niet weten welke toestellen werkelijk worden geïnstalleerd, hoe een kabel op de werf loopt of welke productspecificaties uw elektricien kiest.",[10,1049,1050,1051,155],{},"Werk daarom steeds volgens hetzelfde patroon: ",[14,1052,1053],{},"voorstel maken → preview controleren → toepassen → technisch nakijken",[10,1055,1056,1058,1061],{},[21,1057],{"id":900},[21,1059],{"id":1060},"consumers",[21,1062],{"id":875},[25,1064,1066],{"id":1065},"verbruikers-en-lichtpunten-voorstellen","Verbruikers en lichtpunten voorstellen",[10,1068,1069],{},"In het grondplan zijn hulpmiddelen beschikbaar voor automatische stopcontacten, verlichting, standaarduitrusting en spotrasters. De voorstellen gebruiken de getekende ruimtes en geometrie als basis.",[10,1071,1072],{},"Voor een bruikbaar resultaat:",[37,1074,1075,1078,1081,1084,1087],{},[40,1076,1077],{},"teken gesloten en correct benoemde ruimtes;",[40,1079,1080],{},"stel waar nodig het gewenste aantal of patroon in;",[40,1082,1083],{},"bekijk de voorgestelde posities;",[40,1085,1086],{},"verplaats, voeg toe of verwijder punten volgens het echte ontwerp;",[40,1088,1089],{},"controleer bijzondere zones en vaste toestellen afzonderlijk.",[10,1091,1092],{},"PlanElec voegt niet stilzwijgend ontbrekende toestellen toe. U blijft verantwoordelijk voor het programma van eisen en de uiteindelijke plaatsing.",[1094,1095,1097],"h3",{"id":1096},"schakelketens-automatisch-opbouwen","Schakelketens automatisch opbouwen",[10,1099,1100],{},"Voor vrije schakelaars en lichtpunten binnen één ruimte kan PlanElec een schakelketen voorstellen. Het startpunt is normaal de vrije schakelaar die het dichtst bij een deur ligt; daarna worden nabijgelegen vrije punten gekoppeld.",[10,1102,1103],{},"Controleer altijd welke schakelaar welk licht bedient en pas de volgorde manueel aan wanneer de werkelijke bediening anders is.",[10,1105,1106],{},[21,1107],{"id":1108},"cables",[25,1110,1112],{"id":1111},"kabelspecificaties-en-routes-genereren","Kabelspecificaties en routes genereren",[10,1114,1115],{},"Zodra de elektrische topologie bestaat, kan PlanElec voor iedere ouder-kindverbinding een kabelsegment aanmaken. Een echte verbindings- of aftakdoos splitst de verbinding in afzonderlijke segmenten. Een doos die alleen in de buurt staat, wordt niet automatisch elektrisch in het pad opgenomen.",[10,1117,1118],{},"De automatische routering zoekt per verdieping een korte route langs de getekende muren. Zijn start en einde niet via dezelfde wandcomponent bereikbaar, dan gebruikt de router een directe fallback.",[10,1120,1121],{},"Na het routeren:",[102,1123,1124,1127,1130,1133],{},[40,1125,1126],{},"controleer of de route overeenkomt met de beoogde uitvoering;",[40,1128,1129],{},"voeg of verplaats routepunten waar nodig;",[40,1131,1132],{},"controleer kabeltype, doorsnede en installatiewijze;",[40,1134,1135],{},"vul een manuele lengte in wanneer de berekende route de werkelijkheid niet voldoende benadert.",[10,1137,1138],{},"De berekende lengte voedt de materiaallijst, spanningsvalberekening en validatie. Ze is een nettolengte zonder automatisch snijverlies of reservepercentage.",[10,1140,1141],{},[21,1142],{"id":1143},"circuits",[25,1145,1147],{"id":1146},"verbruikers-automatisch-aan-stroomkringen-toewijzen","Verbruikers automatisch aan stroomkringen toewijzen",[10,1149,1150],{},"De automatische stroomkringtoewijzing maakt een voorstel op basis van de vastgelegde verbruikers en productregels. Onder meer deze keuzes worden ondersteund:",[102,1152,1153,1156,1159,1162,1165,1168],{},[40,1154,1155],{},"standaard licht- en stopcontactpunten worden per ruimte gegroepeerd;",[40,1157,1158],{},"maximaal acht aansluitpunten worden per standaardkring voorzien;",[40,1160,1161],{},"onder andere kookplaat, oven, wasmachine, droogkast, vaatwasser, boiler, warmtepomp en sauna krijgen een toegewijde automaat;",[40,1163,1164],{},"standaardgroepen worden achter 30 mA-differentieelschakelaars geplaatst;",[40,1166,1167],{},"een wallbox krijgt een afzonderlijke 30 mA-RCD en een driefasige automaat; bij gedocumenteerde ingebouwde 6 mA-DC-detectie stelt PlanElec extern type A voor, anders type B;",[40,1169,1170],{},"bij meerdere verdeelkasten kan de toewijzing over boards worden verdeeld.",[10,1172,1173],{},"Bekijk de preview voor u bevestigt. Controleer vooral gemengde kringen, bijzondere toestellen, bestaande handmatige toewijzingen en de toepasbaarheid van de defaults op het concrete project.",[10,1175,1176],{},[21,1177],{"id":1178},"phases",[25,1180,1182],{"id":1181},"lasten-over-fasen-verdelen","Lasten over fasen verdelen",[10,1184,1185],{},"Voor een driefasig of delta-net kan PlanElec lasten over L1, L2 en L3 verdelen. De faseweergave toont de berekende last per fase en waarschuwt bij een duidelijke onbalans.",[10,1187,1188],{},"Dit blijft een modelberekening op basis van de ingevoerde vermogens. Werkelijke gelijktijdigheid, metingen en netvoorwaarden moeten buiten de software worden beoordeeld.",[10,1190,1191],{},[21,1192],{"id":903},[25,1194,1196],{"id":1195},"de-verdeelkast-automatisch-vullen","De verdeelkast automatisch vullen",[10,1198,1199],{},"Automatisch vullen plaatst de bestaande hoofdschakelaar, RCD's en MCB's op vrije DIN-railplaatsen. De standaardvolgorde is hoofd-RCD, groeps-RCD's en vervolgens automaten. De functie houdt standaard ongeveer twintig procent railruimte vrij.",[10,1201,1202],{},"Het verschil met stroomkringtoewijzing is belangrijk:",[102,1204,1205,1211],{},[40,1206,1207,1210],{},[14,1208,1209],{},"Stroomkringtoewijzing"," maakt en koppelt de elektrische beveiligingsstructuur.",[40,1212,1213,1216],{},[14,1214,1215],{},"Automatisch vullen"," rangschikt die bestaande modules fysiek in de kast.",[10,1218,1219],{},"Na automatisch vullen controleert u de gekozen kastgrootte, TE-breedtes, reservecapaciteit, beschermingsketens en verbindingspaden. Expliciete paden via verbindingsdozen worden bij opnieuw vullen bewaard.",[10,1221,1222,1224],{},[21,1223],{"id":938},[21,1225],{"id":1226},"review",[25,1228,1230],{"id":1229},"eindcontrole-van-een-automatisch-voorstel","Eindcontrole van een automatisch voorstel",[10,1232,1233],{},"Loop na elke automatische actie deze punten na:",[37,1235,1236,1242,1248,1254,1260,1266],{},[40,1237,1238,1241],{},[14,1239,1240],{},"Volledigheid:"," zijn alle werkelijke verbruikers, dozen en verdeelkasten gemodelleerd?",[40,1243,1244,1247],{},[14,1245,1246],{},"Topologie:"," klopt elke ouder-kindverbinding en is niets onverbonden?",[40,1249,1250,1253],{},[14,1251,1252],{},"Beveiliging:"," passen RCD, MCB, poolconfiguratie en kabel bij de toepassing?",[40,1255,1256,1259],{},[14,1257,1258],{},"Ruimte:"," zijn routes en posities uitvoerbaar op de werf?",[40,1261,1262,1265],{},[14,1263,1264],{},"Fasen:"," is de verdeling aannemelijk met de ingevoerde vermogens?",[40,1267,1268,1271],{},[14,1269,1270],{},"Documenten:"," blijven situatieplan en eendraadschema na de wijzigingen leesbaar?",[10,1273,1274],{},"De AREI\u002FRGIE-zelfcontrole helpt bij de ondersteunde, op basis van projectdata beslisbare regels. Ze is geen conformiteitsverklaring en vervangt de beoordeling door een elektricien of een officiële keuring niet.",[10,1276,1277,1278,155],{},"Ga daarna verder met ",[21,1279,979],{"href":978},{"title":157,"searchDepth":158,"depth":158,"links":1281},[1282,1286,1287,1288,1289,1290],{"id":1065,"depth":158,"text":1066,"children":1283},[1284],{"id":1096,"depth":1285,"text":1097},3,{"id":1111,"depth":158,"text":1112},{"id":1146,"depth":158,"text":1147},{"id":1181,"depth":158,"text":1182},{"id":1195,"depth":158,"text":1196},{"id":1229,"depth":158,"text":1230},"automation","Gebruik PlanElec-voorstellen voor verbruikers, schakelketens, kabelroutes, stroomkringen, fasen en de verdeelkast zonder de technische controle over te slaan.",{},"\u002Fhelp\u002Fautomatic-planning.nl","9 min",{"title":1042,"description":1292},"automatische-planning","help\u002Fautomatic-planning.nl",[1300,1036,1301,1302,1303,1037,1304],"automatische planning","kabelroute","stroomkring","faseverdeling","DIN-rail","YYloXt8Ku2ew2gXNJSN6HIK4S1nkSgIWDZ1eZxMbb88",{"id":1307,"title":1308,"body":1309,"category":959,"description":1616,"extension":166,"guideId":1617,"locale":168,"meta":1618,"navigation":170,"order":1285,"path":1619,"publishedAt":1029,"readTime":174,"seo":1620,"slug":1621,"stem":1622,"tags":1623,"updatedAt":1029,"__hash__":1631},"help\u002Fhelp\u002Fdocument-exports.nl.md","Documenten exporteren en een werkdossier samenstellen",{"type":7,"value":1310,"toc":1605},[1311,1314,1318,1322,1410,1417,1421,1424,1427,1444,1448,1452,1455,1458,1463,1466,1469,1472,1486,1490,1493,1513,1516,1523,1526,1534,1539,1543,1546,1549,1554,1558,1561,1584,1587,1591,1594],[10,1312,1313],{},"De exportwerkruimte brengt de documenten uit hetzelfde projectmodel samen. U kunt documenten afzonderlijk downloaden of geselecteerde onderdelen bundelen in één werkdossier.",[10,1315,1316],{},[21,1317],{"id":959},[25,1319,1321],{"id":1320},"status-in-één-oogopslag","Status in één oogopslag",[1323,1324,1325,1341],"table",{},[1326,1327,1328],"thead",{},[1329,1330,1331,1335,1338],"tr",{},[1332,1333,1334],"th",{},"Document",[1332,1336,1337],{},"Huidige status",[1332,1339,1340],{},"Belangrijk om te weten",[1342,1343,1344,1356,1366,1377,1388,1399],"tbody",{},[1329,1345,1346,1350,1353],{},[1347,1348,1349],"td",{},"Eendraadschema PDF",[1347,1351,1352],{},"Beschikbaar",[1347,1354,1355],{},"Meerdere pagina's mogelijk; controleer schaal, symbolen en titelblok.",[1329,1357,1358,1361,1363],{},[1347,1359,1360],{},"Situatieschema PDF",[1347,1362,1352],{},[1347,1364,1365],{},"Gebaseerd op het getekende grondplan en de geplaatste symbolen.",[1329,1367,1368,1371,1374],{},[1347,1369,1370],{},"AREI\u002FRGIE-zelfcontrolerapport",[1347,1372,1373],{},"Beschikbaar, adviserend",[1347,1375,1376],{},"Geen conformiteitsattest en geen vervanging voor de officiële keuring.",[1329,1378,1379,1382,1385],{},[1347,1380,1381],{},"Stroomkring-, kabel- en materiaallijst",[1347,1383,1384],{},"Pilotworkflow",[1347,1386,1387],{},"Modelgebaseerde, fabrikantneutrale lijsten; nog geen bestellingsvrijgave.",[1329,1389,1390,1393,1396],{},[1347,1391,1392],{},"Verdeelkast-PDF",[1347,1394,1395],{},"Feature-flag",[1347,1397,1398],{},"Alleen zichtbaar wanneer de functie actief is en kastgegevens aanwezig zijn.",[1329,1400,1401,1404,1407],{},[1347,1402,1403],{},"Samengevoegd installatiedossier",[1347,1405,1406],{},"Pilot\u002Fwerkstatus",[1347,1408,1409],{},"Lokale samenstelling; een versioneerbare finale serversnapshot en formele acceptatie blijven open.",[10,1411,1412,1414],{},[21,1413],{"id":938},[21,1415],{"id":1416},"single-line",[25,1418,1420],{"id":1419},"eendraadschema-als-pdf","Eendraadschema als PDF",[10,1422,1423],{},"Het eendraadschema gebruikt de elektrische topologie, beveiligingstoestellen, stroomkringen, kabelgegevens en verbruikers. Grotere installaties worden over meerdere pagina's verdeeld.",[10,1425,1426],{},"Controleer vóór downloaden:",[102,1428,1429,1432,1435,1438,1441],{},[40,1430,1431],{},"of elk verbruikerpad bij de juiste automaat en RCD uitkomt;",[40,1433,1434],{},"of kabeltype, doorsnede en labels ingevuld zijn;",[40,1436,1437],{},"of reservemodules niet als actieve stroomkring verschijnen;",[40,1439,1440],{},"of project- en installateurgegevens in het titelblok kloppen;",[40,1442,1443],{},"of geen inhoud aan een paginarand wordt afgesneden.",[10,1445,1446],{},[21,1447],{"id":833},[25,1449,1451],{"id":1450},"situatieschema-als-pdf","Situatieschema als PDF",[10,1453,1454],{},"Het situatieschema toont de getekende ruimtes, openingen en elektrische symbolen op hun locatie. Controleer alle verdiepingen afzonderlijk en let op overlappende labels, ontbrekende apparaten en de leesbaarheid op het gekozen A4- of A3-formaat.",[10,1456,1457],{},"Het situatieschema en eendraadschema delen projectnotities en andere titelblokgegevens. Corrigeer die gegevens in het project in plaats van afzonderlijk in een PDF.",[10,1459,1460],{},[21,1461],{"id":1462},"self-check",[25,1464,1370],{"id":1465},"areirgie-zelfcontrolerapport",[10,1467,1468],{},"Het rapport vat de bevindingen samen die PlanElec met de ingevoerde gegevens en de ondersteunde regels kan beoordelen. Het vermeldt ook wanneer een controle niet gestart, onvolledig of buiten de huidige dekking valt.",[10,1470,1471],{},"Een rapport zonder gevonden fout betekent niet dat de installatie AREI\u002FRGIE-conform is. Metingen, bewijsstukken, omstandigheden ter plaatse en niet gemodelleerde regels vallen buiten een softwarecontrole. Alleen een erkend controleorganisme voert de officiële keuring uit.",[10,1473,1474,1477,1480,1483],{},[21,1475],{"id":1476},"lists",[21,1478],{"id":1479},"circuit-list",[21,1481],{"id":1482},"cable-list",[21,1484],{"id":1485},"material-list",[25,1487,1489],{"id":1488},"stroomkring-kabel-en-materiaallijsten","Stroomkring-, kabel- en materiaallijsten",[10,1491,1492],{},"Deze lijsten zijn in de centrale pilotworkflow beschikbaar:",[102,1494,1495,1501,1507],{},[40,1496,1497,1500],{},[14,1498,1499],{},"Stroomkringenlijst:"," overzicht van de gemodelleerde kringen en beveiligingen.",[40,1502,1503,1506],{},[14,1504,1505],{},"Kabellijst:"," kabelsegmenten met specificatie en berekende of manuele lengte.",[40,1508,1509,1512],{},[14,1510,1511],{},"Materiaallijst:"," fabrikantneutrale hoeveelheden voor onder meer schakelmateriaal, aansluitingen, bescherming, kast, accessoires en nettokabellengtes.",[10,1514,1515],{},"De materiaallijst kan per categorie of ruimte worden bekeken en maakt standaardaannames zichtbaar. Ze bevat geen prijzen of concrete fabrikantartikelen. Nettokabellengtes hebben geen automatisch snijverlies- of reservepercentage. Gebruik de lijst daarom als controle- en offertestartpunt, niet als bestelbon.",[10,1517,1518,1520],{},[21,1519],{"id":903},[21,1521],{"id":1522},"cabinet-pdf",[25,1524,1392],{"id":1525},"verdeelkast-pdf",[10,1527,1528,1529,1533],{},"De PDF-weergave van de verdeelkast is alleen beschikbaar wanneer de ",[1530,1531,1532],"code",{},"cabinet_export","-feature-flag actief is en het project kastgegevens bevat. Als de optie ontbreekt, is dat geen exportfout: de functie is dan niet voor die omgeving vrijgegeven.",[10,1535,1536],{},[21,1537],{"id":1538},"dossier",[25,1540,1542],{"id":1541},"een-installatiedossier-samenstellen","Een installatiedossier samenstellen",[10,1544,1545],{},"In de dossier-builder selecteert u de gewenste documenten. PlanElec maakt lokaal een voorblad, documentoverzicht en doorlopende paginanummering en voegt de geselecteerde PDF's in een vaste volgorde samen.",[10,1547,1548],{},"Dit is momenteel een werk- en controlestatus. De versioneerbare serversnapshot en formeel beoordeelde praktijkoutputs die voor een finaal dossier nodig zijn, zijn nog niet algemeen vrijgegeven.",[10,1550,1551],{},[21,1552],{"id":1553},"metadata",[25,1555,1557],{"id":1556},"projectmetadata-controleren","Projectmetadata controleren",[10,1559,1560],{},"Open vanuit de export de projectgegevens en controleer minstens:",[37,1562,1563,1566,1569,1572,1575,1578,1581],{},[40,1564,1565],{},"klant en installatieadres;",[40,1567,1568],{},"installateur en contactgegevens;",[40,1570,1571],{},"controleorganisme;",[40,1573,1574],{},"Belgische EAN;",[40,1576,1577],{},"woon- of niet-wooninstallatie en AC\u002FDC-aanduiding;",[40,1579,1580],{},"planformaat, revisie en projectnotities;",[40,1582,1583],{},"logo, indien gebruikt.",[10,1585,1586],{},"Een ongeldige EAN wordt niet als geldige nummering uitgevoerd, maar blokkeert in Early Access de download niet automatisch.",[25,1588,1590],{"id":1589},"laatste-controle-vóór-delen","Laatste controle vóór delen",[10,1592,1593],{},"Open het gedownloade bestand buiten PlanElec en bekijk elke pagina. Controleer paginavolgorde, leesbaarheid, metadata, waarschuwingen en ontbrekende onderdelen. Bewaar de projectversie waarmee het document is gemaakt en laat het resultaat beoordelen door de verantwoordelijke elektricien.",[10,1595,1596,1597,1601,1602,155],{},"Wilt u eerst het projectmodel nalopen? Begin bij ",[21,1598,1600],{"href":1599},"\u002Fhelp\u002Faan-de-slag","Aan de slag"," of lees hoe u ",[21,1603,1604],{"href":894},"automatische planning controleert",{"title":157,"searchDepth":158,"depth":158,"links":1606},[1607,1608,1609,1610,1611,1612,1613,1614,1615],{"id":1320,"depth":158,"text":1321},{"id":1419,"depth":158,"text":1420},{"id":1450,"depth":158,"text":1451},{"id":1465,"depth":158,"text":1370},{"id":1488,"depth":158,"text":1489},{"id":1525,"depth":158,"text":1392},{"id":1541,"depth":158,"text":1542},{"id":1556,"depth":158,"text":1557},{"id":1589,"depth":158,"text":1590},"Bekijk welke PDF-documenten PlanElec maakt, welke outputs beschikbaar of pilot zijn en wat u vóór delen of keuring moet controleren.","document-exports",{},"\u002Fhelp\u002Fdocument-exports.nl",{"title":1308,"description":1616},"documenten-exporteren","help\u002Fdocument-exports.nl",[1624,1038,1625,1626,1627,1628,1629,1630],"PDF-export","situatieschema","zelfcontrole","stroomkringen","kabellijst","materiaallijst","installatiedossier","wAYpphMgOzBVC15J3rkGcyxue3AcUx9lzOZLAuIlp0Y",{"id":1633,"title":1634,"body":1635,"category":2412,"description":2413,"extension":166,"guideId":2414,"locale":168,"meta":2415,"navigation":170,"order":2416,"path":2417,"publishedAt":2418,"readTime":2419,"seo":2420,"slug":2421,"stem":2422,"tags":2423,"updatedAt":2429,"__hash__":2430},"help\u002Fhelp\u002Fself-check-coverage.nl.md","Wat controleert de AREI-zelfcontrole van PlanElec?",{"type":7,"value":1636,"toc":2397},[1637,1640,1647,1653,1658,1662,1677,1680,1684,1896,1900,1954,1958,2026,2030,2071,2075,2142,2146,2174,2178,2219,2223,2326,2330,2333,2339,2345,2351,2357,2361,2364,2387,2391,2394],[10,1638,1639],{},"In PlanElec zitten twee verschillende dingen die makkelijk verward worden.",[10,1641,1642,1643,1646],{},"De ",[14,1644,1645],{},"geïntegreerde regeltekst"," is volledig: AREI Boek 1, Versie 06 (K.B. 06.10.2025, van kracht sinds 1 april 2026), Delen 1 tot en met 9, in het Nederlands, Frans en Duits. Die kunt u in de toepassing raadplegen.",[10,1648,1642,1649,1652],{},[14,1650,1651],{},"automatische zelfcontrole"," dekt daarvan slechts een deel. Deze pagina zegt precies welk deel dat is. Wij vermelden de regels die getoetst worden én de gebieden waar de toepassing geen uitspraak doet, omdat een onvolledige controle die zich als volledig voordoet gevaarlijker is dan helemaal geen controle.",[782,1654,1655],{},[10,1656,1657],{},"De zelfcontrole is een voorbereiding. Het officiële oordeel komt uitsluitend van een erkend controleorganisme.",[25,1659,1661],{"id":1660},"wat-automatisch-getoetst-wordt","Wat automatisch getoetst wordt",[10,1663,1664,1665,1668,1669,1672,1673,1676],{},"De toepassing kent op dit moment ",[14,1666,1667],{},"38 controles",". Daarvan verwijzen er ",[14,1670,1671],{},"24"," naar een concreet AREI-artikel; de overige ",[14,1674,1675],{},"14"," zijn praktijkregels of plausibiliteitscontroles die wij als zodanig aanduiden en die geen reglementaire verplichting zijn.",[10,1678,1679],{},"Een controle levert pas een resultaat op wanneer de nodige projectgegevens ingevuld zijn. Ontbreken die, dan markeert het rapport de controle als onvolledig — nooit als geslaagd.",[1094,1681,1683],{"id":1682},"beveiliging","Beveiliging",[1323,1685,1686,1702],{},[1326,1687,1688],{},[1329,1689,1690,1693,1696,1699],{},[1332,1691,1692],{},"Controle",[1332,1694,1695],{},"Wat er getoetst wordt",[1332,1697,1698],{},"Basis",[1332,1700,1701],{},"Ernst",[1342,1703,1704,1718,1731,1744,1757,1770,1782,1795,1808,1821,1833,1845,1858,1870,1883],{},[1329,1705,1706,1709,1712,1715],{},[1347,1707,1708],{},"Hoofddifferentieelschakelaar",[1347,1710,1711],{},"Aan het hoofd van de installatie moet een differentieelschakelaar van hoogstens 300 mA aanwezig zijn.",[1347,1713,1714],{},"AREI 4.2.4.3",[1347,1716,1717],{},"Fout",[1329,1719,1720,1723,1726,1729],{},[1347,1721,1722],{},"Max. stroomkringen per hooggevoelige differentieel",[1347,1724,1725],{},"Hoogstens 8 eindstroomkringen per hooggevoelige differentieelschakelaar (≤ 30 mA).",[1347,1727,1728],{},"AREI 4.2.4.3.b",[1347,1730,1717],{},[1329,1732,1733,1736,1739,1742],{},[1347,1734,1735],{},"Nominale waarden van rolluikactoren",[1347,1737,1738],{},"Rolluikactoren op DIN-rail vragen een automaat of aardlekautomaat stroomopwaarts; beveiligings- en motorlast blijven binnen de gecatalogiseerde ingangs- en kanaalwaarden.",[1347,1740,1741],{},"Praktijkregel",[1347,1743,1717],{},[1329,1745,1746,1749,1752,1755],{},[1347,1747,1748],{},"Beveiliging van laadpunten (EV-laden)",[1347,1750,1751],{},"Een laadpunt vraagt een eigen stroomkring, een toegewijde differentieelschakelaar en buiten minstens IP44.",[1347,1753,1754],{},"AREI 7.22.4",[1347,1756,1717],{},[1329,1758,1759,1762,1765,1767],{},[1347,1760,1761],{},"Selectiviteit van differentieelschakelaars (praktijkaanbeveling)",[1347,1763,1764],{},"Praktijkadvies: stem gevoeligheid en tijd af tussen boven- en ondergeschikte differentieelschakelaars (IEC 60364-5-53).",[1347,1766,1741],{},[1347,1768,1769],{},"Waarschuwing",[1329,1771,1772,1775,1778,1780],{},[1347,1773,1774],{},"30mA-differentieel voor stopcontactkringen",[1347,1776,1777],{},"Alle stopcontactkringen moeten door een differentieelschakelaar van 30 mA beschermd zijn.",[1347,1779,1728],{},[1347,1781,1717],{},[1329,1783,1784,1787,1790,1793],{},[1347,1785,1786],{},"Overspanningsbeveiliging (SPD)",[1347,1788,1789],{},"Een overspanningsbeveiliging (SPD) wordt beoordeeld op aanwezigheid; het AREI legt geen algemene plicht op.",[1347,1791,1792],{},"AREI 4.5.1",[1347,1794,1769],{},[1329,1796,1797,1800,1803,1806],{},[1347,1798,1799],{},"Hoofdschakelaar min. 40 A",[1347,1801,1802],{},"Een hoofdschakelaar moet aanwezig zijn en in huishoudelijke installaties minstens 40 A bedragen.",[1347,1804,1805],{},"AREI 5.3.5.1.b",[1347,1807,1717],{},[1329,1809,1810,1813,1816,1819],{},[1347,1811,1812],{},"Hoofddifferentieel min. 40 A",[1347,1814,1815],{},"De differentieelschakelaar aan het voedingspunt moet minstens 40 A nominale stroom hebben.",[1347,1817,1818],{},"AREI 5.3.5.3.a",[1347,1820,1717],{},[1329,1822,1823,1826,1829,1831],{},[1347,1824,1825],{},"Verdeelbordindeling",[1347,1827,1828],{},"Verdeelkast: bezetting binnen het aantal modules, een differentieelschakelaar per rij en een reserve van ongeveer 20 %.",[1347,1830,1741],{},[1347,1832,1769],{},[1329,1834,1835,1838,1841,1843],{},[1347,1836,1837],{},"Ingebouwde wandverwarming: differentieel 100 mA",[1347,1839,1840],{},"In wanden ingebouwde verwarmingsweerstanden boven 25 V AC vragen een afzonderlijke differentieelschakelaar van 100 mA.",[1347,1842,1728],{},[1347,1844,1717],{},[1329,1846,1847,1850,1853,1856],{},[1347,1848,1849],{},"Poolconfiguratie van huishoudelijke installatie",[1347,1851,1852],{},"Eenpolige automaten zijn in Belgische woningen met sterschakeling niet toegelaten; gebruik 1P+N.",[1347,1854,1855],{},"AREI 4.4.4.2",[1347,1857,1769],{},[1329,1859,1860,1863,1866,1868],{},[1347,1861,1862],{},"Uitschakelkarakteristiek tegenover belastingstype",[1347,1864,1865],{},"Praktijkadvies: de karakteristiek B, C of D van de automaat moet passen bij het type belasting.",[1347,1867,1741],{},[1347,1869,1769],{},[1329,1871,1872,1875,1878,1881],{},[1347,1873,1874],{},"Back-upbeveiliging van voedingsleidingen tussen verdeelborden",[1347,1876,1877],{},"Een voedingsleiding naar een onderverdeler vraagt een eigen beveiliging in de voedende kast en een consistente koppeling.",[1347,1879,1880],{},"AREI 4.4.1.4",[1347,1882,1717],{},[1329,1884,1885,1888,1891,1894],{},[1347,1886,1887],{},"Uitschakelvermogen tegenover kortsluitstroom",[1347,1889,1890],{},"Het uitschakelvermogen van elke automaat moet de verwachte kortsluitstroom aankunnen; enkel gecontroleerd bij ingevulde waarde.",[1347,1892,1893],{},"AREI 5.3.5.5",[1347,1895,1717],{},[1094,1897,1899],{"id":1898},"aarding","Aarding",[1323,1901,1902,1914],{},[1326,1903,1904],{},[1329,1905,1906,1908,1910,1912],{},[1332,1907,1692],{},[1332,1909,1695],{},[1332,1911,1698],{},[1332,1913,1701],{},[1342,1915,1916,1929,1942],{},[1329,1917,1918,1921,1924,1927],{},[1347,1919,1920],{},"Hoofdequipotentiale verbinding",[1347,1922,1923],{},"Er moet een hoofdequipotentiaalverbinding (aardingsrail) aanwezig zijn.",[1347,1925,1926],{},"AREI 4.2.3.2",[1347,1928,1717],{},[1329,1930,1931,1934,1937,1940],{},[1347,1932,1933],{},"Aardingselektrode (aardingslus\u002Faardpen)",[1347,1935,1936],{},"Bij een TT- of IT-net moet een aardingselektrode gedocumenteerd zijn.",[1347,1938,1939],{},"AREI 4.2.3",[1347,1941,1717],{},[1329,1943,1944,1947,1950,1952],{},[1347,1945,1946],{},"Plausibiliteit van aarding en netaansluiting",[1347,1948,1949],{},"Plausibiliteitscontrole: een openbare huishoudelijke 3×230 V-aansluiting met een opgeslagen TN-stelsel vraagt nazicht.",[1347,1951,1741],{},[1347,1953,1769],{},[1094,1955,1957],{"id":1956},"kabels-en-dimensionering","Kabels en dimensionering",[1323,1959,1960,1972],{},[1326,1961,1962],{},[1329,1963,1964,1966,1968,1970],{},[1332,1965,1692],{},[1332,1967,1695],{},[1332,1969,1698],{},[1332,1971,1701],{},[1342,1973,1974,1987,2000,2013],{},[1329,1975,1976,1979,1982,1985],{},[1347,1977,1978],{},"Kabeldoorsnede",[1347,1980,1981],{},"De kabeldoorsnede moet passen bij de nominale stroom van de beveiliging.",[1347,1983,1984],{},"AREI 5.2.2",[1347,1986,1717],{},[1329,1988,1989,1992,1995,1998],{},[1347,1990,1991],{},"Spanningsval (ΔU)",[1347,1993,1994],{},"Spanningsval berekend uit kabellengte: richtwaarde 3 % voor verlichting en 5 % voor andere eindstroomkringen.",[1347,1996,1997],{},"AREI 5.2.5",[1347,1999,1717],{},[1329,2001,2002,2005,2008,2011],{},[1347,2003,2004],{},"CPR-brandklasse van kabels",[1347,2006,2007],{},"Afzonderlijk geplaatste kabels moeten de eigenschap F1 hebben of minstens CPR-klasse Eca halen; klasse Fca is niet toegestaan.",[1347,2009,2010],{},"AREI 5.2.7.2",[1347,2012,1717],{},[1329,2014,2015,2018,2021,2024],{},[1347,2016,2017],{},"Bekabeling in holle wanden: Cca\u002FPreflex",[1347,2019,2020],{},"Kabels in bouwkundige holle ruimtes lopen in een mantelbuis (Preflex) of halen minstens CPR-klasse Cca.",[1347,2022,2023],{},"AREI 4.3.3.5.b",[1347,2025,1717],{},[1094,2027,2029],{"id":2028},"belasting-van-stroomkringen","Belasting van stroomkringen",[1323,2031,2032,2044],{},[1326,2033,2034],{},[1329,2035,2036,2038,2040,2042],{},[1332,2037,1692],{},[1332,2039,1695],{},[1332,2041,1698],{},[1332,2043,1701],{},[1342,2045,2046,2059],{},[1329,2047,2048,2051,2054,2057],{},[1347,2049,2050],{},"Max. contactpunten per eindstroomkring",[1347,2052,2053],{},"Hoogstens 8 stopcontacten en vaste toestellen per eindstroomkring; zuivere lichtpunten tellen niet mee.",[1347,2055,2056],{},"AREI 5.3.5.2b",[1347,2058,1717],{},[1329,2060,2061,2064,2067,2069],{},[1347,2062,2063],{},"Faseonbalans",[1347,2065,2066],{},"Praktijkadvies: de onbalans tussen de fasen blijft best onder 30 %.",[1347,2068,1741],{},[1347,2070,1769],{},[1094,2072,2074],{"id":2073},"ruimtes-en-zones","Ruimtes en zones",[1323,2076,2077,2089],{},[1326,2078,2079],{},[1329,2080,2081,2083,2085,2087],{},[1332,2082,1692],{},[1332,2084,1695],{},[1332,2086,1698],{},[1332,2088,1701],{},[1342,2090,2091,2104,2117,2130],{},[1329,2092,2093,2096,2099,2102],{},[1347,2094,2095],{},"30mA-beveiliging voor vochtige ruimten",[1347,2097,2098],{},"Stopcontacten in vochtige ruimtes moeten door een differentieelschakelaar van 30 mA beschermd zijn.",[1347,2100,2101],{},"AREI 4.2.4.4",[1347,2103,1717],{},[1329,2105,2106,2109,2112,2115],{},[1347,2107,2108],{},"30mA-differentieel voor badkamerkringen",[1347,2110,2111],{},"Alle stroomkringen in badkamers en vochtige ruimtes moeten door een differentieelschakelaar van 30 mA beschermd zijn.",[1347,2113,2114],{},"AREI 7.1.4.3",[1347,2116,1717],{},[1329,2118,2119,2122,2125,2128],{},[1347,2120,2121],{},"Badkamerzones 0\u002F1\u002F2: toegelaten materieel",[1347,2123,2124],{},"In badkamervolumes 0, 1 en 2 is enkel bepaald materieel toegelaten; verdeelkasten zijn er verboden.",[1347,2126,2127],{},"AREI 7.1.5.2",[1347,2129,1717],{},[1329,2131,2132,2135,2138,2140],{},[1347,2133,2134],{},"Rookmelderdekking (aanbeveling)",[1347,2136,2137],{},"Niet-bindend advies op basis van de gewestelijke woningregels; het AREI zelf schrijft rookmelders voor woningen niet voor.",[1347,2139,1741],{},[1347,2141,1769],{},[1094,2143,2145],{"id":2144},"topologie-en-besturing","Topologie en besturing",[1323,2147,2148,2160],{},[1326,2149,2150],{},[1329,2151,2152,2154,2156,2158],{},[1332,2153,1692],{},[1332,2155,1695],{},[1332,2157,1698],{},[1332,2159,1701],{},[1342,2161,2162],{},[1329,2163,2164,2167,2170,2172],{},[1347,2165,2166],{},"Stuurwegen van elektrische rolluiken",[1347,2168,2169],{},"Plausibiliteitscontrole: directe schakelaars, actoringangen, centrale bedieningen en aandrijvingstypes vormen samen een samenhangend besturingstraject.",[1347,2171,1741],{},[1347,2173,1717],{},[1094,2175,2177],{"id":2176},"fotovoltaïsche-installatie","Fotovoltaïsche installatie",[1323,2179,2180,2192],{},[1326,2181,2182],{},[1329,2183,2184,2186,2188,2190],{},[1332,2185,1692],{},[1332,2187,1695],{},[1332,2189,1698],{},[1332,2191,1701],{},[1342,2193,2194,2207],{},[1329,2195,2196,2199,2202,2205],{},[1347,2197,2198],{},"Conformiteit van PV-installatie",[1347,2200,2201],{},"PV-installatie: anti-eilandbedrijf, aarding van de modulekaders, waarschuwingsborden en kenmerking van DC- en AC-geleiders.",[1347,2203,2204],{},"AREI 7.112.2",[1347,2206,1717],{},[1329,2208,2209,2212,2215,2217],{},[1347,2210,2211],{},"Somstroom in verdeelborden met meerdere voedingsbronnen",[1347,2213,2214],{},"Bij een verdeelkast met eigen opwekking worden net- en bronstroom per fase opgeteld op gemeenschappelijk belaste secties.",[1347,2216,1741],{},[1347,2218,1717],{},[1094,2220,2222],{"id":2221},"volledigheid-van-het-dossier","Volledigheid van het dossier",[1323,2224,2225,2237],{},[1326,2226,2227],{},[1329,2228,2229,2231,2233,2235],{},[1332,2230,1692],{},[1332,2232,1695],{},[1332,2234,1698],{},[1332,2236,1701],{},[1342,2238,2239,2251,2263,2276,2288,2301,2314],{},[1329,2240,2241,2244,2247,2249],{},[1347,2242,2243],{},"Volledige verbindingen",[1347,2245,2246],{},"Elk element in het schema moet aangesloten zijn; losse knooppunten wijzen op een onvolledig model.",[1347,2248,1741],{},[1347,2250,1769],{},[1329,2252,2253,2256,2259,2261],{},[1347,2254,2255],{},"Min. aantal verlichtingskringen",[1347,2257,2258],{},"Praktijkadvies: minstens twee verlichtingsstroomkringen per wooneenheid.",[1347,2260,1741],{},[1347,2262,1769],{},[1329,2264,2265,2268,2271,2274],{},[1347,2266,2267],{},"Afzonderlijke stroomkringen voor grootverbruikers",[1347,2269,2270],{},"Grote toestellen zoals wasmachine, droogkast, vaatwasser, kookplaat en oven vragen elk een eigen stroomkring.",[1347,2272,2273],{},"AREI 4.3.3.3",[1347,2275,1717],{},[1329,2277,2278,2281,2284,2286],{},[1347,2279,2280],{},"Installatiedossier (AREI 9.1.2)",[1347,2282,2283],{},"Het installatiedossier vraagt een eendraadschema, een situatieplan en een volledige cartouche; PV vraagt bijkomende documenten.",[1347,2285,1741],{},[1347,2287,1769],{},[1329,2289,2290,2293,2296,2299],{},[1347,2291,2292],{},"Plaatsing van verbindings-\u002Faftakdozen",[1347,2294,2295],{},"Structurele aftakdozen moeten precies één keer en consistent in het schema voorkomen.",[1347,2297,2298],{},"AREI 3.1.2.3",[1347,2300,1769],{},[1329,2302,2303,2306,2309,2311],{},[1347,2304,2305],{},"Niet-gekoppelde elektrische grondplansymbolen",[1347,2307,2308],{},"Toestellen op het grondplan zonder koppeling aan de elektrische topologie worden als informatie gemeld.",[1347,2310,1741],{},[1347,2312,2313],{},"Informatie",[1329,2315,2316,2319,2322,2324],{},[1347,2317,2318],{},"Plausibiliteit van schakelgroepen",[1347,2320,2321],{},"Plausibiliteitscontrole: een schakelgroep bevat minstens één schakelaar en minstens één geschakelde belasting.",[1347,2323,1741],{},[1347,2325,1769],{},[25,2327,2329],{"id":2328},"wat-de-zelfcontrole-niet-beoordeelt","Wat de zelfcontrole niet beoordeelt",[10,2331,2332],{},"Deze onderdelen van Boek 1 blijven bewust buiten de automatische toetsing:",[10,2334,2335,2338],{},[14,2336,2337],{},"Bijzondere installaties en ruimtes (Deel 7)."," Van de veertien hoofdstukken raakt PlanElec er drie, en die telkens gedeeltelijk: ruimtes met bad of douche (7.1), voeding van elektrische wegvoertuigen (7.22) en huishoudelijke fotovoltaïsche installaties (7.112). Niet gedekt zijn zwembaden (7.2), sauna's (7.3), werf- en buiteninstallaties (7.4), enge geleidende ruimtes (7.6), campings (7.8), jachthavens (7.9), foorinstallaties (7.11), fonteinen (7.100), stationerende voertuigen (7.101), explosieve atmosferen (7.102) en industriële accumulatorbatterijen (7.103).",[10,2340,2341,2344],{},[14,2342,2343],{},"De gelijkstroomzijde."," Het model kent geen afzonderlijke rollen voor de geleiders L+, L-, M, PEM en PEL. Daardoor zijn geleiderkeuze, kleurstelling, gecombineerde beschermingsgeleiders, DC-differentieelgevoeligheid, de bescherming van de M-geleider en permanente isolatiebewaking bij een IT-stelsel niet toetsbaar. Voor PV blijft dat handwerk.",[10,2346,2347,2350],{},[14,2348,2349],{},"De overgangsbepalingen van artikel 59 en 69."," Of een uitzondering voor een bestaande installatie geldt, hangt af van gegevens die niet uit een eendraadschema af te leiden zijn — onder meer de PEN-doorsnede, het werkelijke begin van de uitvoering ter plaatse en de aanwezigheid van een bewakingstoestel. PlanElec houdt wel rekening met de versoepelingen van Deel 8 door bepaalde bevindingen bij bestaande delen als aanwijzing te tonen in plaats van als fout, maar beslist de uitzondering niet zelf.",[10,2352,2353,2356],{},[14,2354,2355],{},"Controles van installaties (Deel 6) en de gedragsvoorschriften (Deel 9)"," vallen buiten het bereik van een planningsinstrument. Enkel de samenstelling van het installatiedossier wordt getoetst.",[25,2358,2360],{"id":2359},"wat-software-principieel-niet-kan-vaststellen","Wat software principieel niet kan vaststellen",[10,2362,2363],{},"Ook na verdere uitbreiding van het model blijven deze punten afhankelijk van meting, inzage of visuele controle ter plaatse:",[102,2365,2366,2369,2372,2375,2378,2381,2384],{},[40,2367,2368],{},"de werkelijke bedrading, de doorverbinding en de polariteit van de geleiders;",[40,2370,2371],{},"de uitschakelkarakteristieken en de DC-geschiktheid van de effectief geplaatste toestellen;",[40,2373,2374],{},"de isolatiemeting en de werking van een permanent isolatiebewakingstoestel;",[40,2376,2377],{},"de mechanische en chemische weerstand en de corrosietoestand van de aarding;",[40,2379,2380],{},"de doeltreffendheid van de automatische uitschakeling en de reële aardingsimpedantie;",[40,2382,2383],{},"de geschiktheid en de certificering van omvormers, batterijen en PV-componenten;",[40,2385,2386],{},"de zone-indeling, de risicobeoordeling en de omstandigheden ter plaatse.",[25,2388,2390],{"id":2389},"wat-dit-betekent-voor-uw-keuring","Wat dit betekent voor uw keuring",[10,2392,2393],{},"Gebruik de zelfcontrole om vermijdbare fouten vroeg te vinden: een ontbrekende differentieelschakelaar, een doorsnede die niet bij de beveiliging past, te veel contactpunten op één kring, een onvolledig dossier. Dat zijn precies de bevindingen die anders pas bij de keuring boven water komen.",[10,2395,2396],{},"Reken er niet op voor de gevallen hierboven. Daar blijven uw vakkennis en het oordeel van het controleorganisme doorslaggevend.",{"title":157,"searchDepth":158,"depth":158,"links":2398},[2399,2409,2410,2411],{"id":1660,"depth":158,"text":1661,"children":2400},[2401,2402,2403,2404,2405,2406,2407,2408],{"id":1682,"depth":1285,"text":1683},{"id":1898,"depth":1285,"text":1899},{"id":1956,"depth":1285,"text":1957},{"id":2028,"depth":1285,"text":2029},{"id":2073,"depth":1285,"text":2074},{"id":2144,"depth":1285,"text":2145},{"id":2176,"depth":1285,"text":2177},{"id":2221,"depth":1285,"text":2222},{"id":2328,"depth":158,"text":2329},{"id":2359,"depth":158,"text":2360},{"id":2389,"depth":158,"text":2390},"compliance","De volledige lijst van de regels die PlanElec automatisch toetst — en een even expliciete lijst van wat de zelfcontrole niet beoordeelt.","self-check-coverage",{},4,"\u002Fhelp\u002Fself-check-coverage.nl","2026-08-17","7 min",{"title":1634,"description":2413},"wat-controleert-de-zelfcontrole","help\u002Fself-check-coverage.nl",[2424,2425,1626,2426,2427,2428],"AREI","RGIE","keuring","dekking","validatie","2026-08-18","AU3cXEXUP3O5l0mBt5hsPQdLzsHo-qitq2dJix7PNvo",{"id":2432,"title":2433,"body":2434,"category":164,"description":2595,"extension":166,"guideId":2596,"locale":168,"meta":2597,"navigation":170,"order":2598,"path":2599,"publishedAt":173,"readTime":2419,"seo":2600,"slug":2601,"stem":2602,"tags":2603,"updatedAt":173,"__hash__":2610},"help\u002Fhelp\u002Ffloorplan-import-calibration.nl.md","Grondplan importeren en kalibreren",{"type":7,"value":2435,"toc":2589},[2436,2443,2448,2452,2461,2481,2484,2489,2493,2517,2520,2546,2549,2553,2556,2559,2573,2576,2580,2583],[10,2437,2438,2439,2442],{},"Een geïmporteerd plan is in PlanElec een ",[14,2440,2441],{},"referentielaag",". Muren, ruimtes en elektrische symbolen tekent u daarboven als bewerkbare PlanElec-gegevens. Daardoor blijft de export leesbaar wanneer u het oorspronkelijke plan later verbergt of vervangt.",[10,2444,2445],{},[21,2446],{"id":2447},"import",[25,2449,2451],{"id":2450},"een-planreferentie-importeren","Een planreferentie importeren",[10,2453,31,2454,2456,2457,2460],{},[14,2455,34],{}," de ",[14,2458,2459],{},"Galerij"," en kies importeren. U kunt PNG-, JPEG- en WebP-afbeeldingen, afzonderlijke PDF-pagina's en DXF-tekeningen selecteren en aan een verdieping koppelen.",[37,2462,2463,2466,2469,2472],{},[40,2464,2465],{},"Kies het bestand en de doelverdieping.",[40,2467,2468],{},"Kies bij een PDF de benodigde pagina's; bij een DXF kunt u overbodige tekenlagen uitschakelen.",[40,2470,2471],{},"Rond de import af. Een bestand met een fout kunt u opnieuw proberen.",[40,2473,2474,2475,2478,2479,155],{},"Kies ",[14,2476,2477],{},"Instellen"," voor een afzonderlijke laag. Na één import opent de lagenwerkbank meteen; na een batch opent u die zelf via ",[14,2480,2477],{},[10,2482,2483],{},"DXF wordt in de browser als referentiebeeld verwerkt. Model Space en de gekozen lagen tellen mee; DWG-bestanden worden niet geïmporteerd. Controleer dus of de uitsnede werkelijk het gewenste grondplan bevat.",[10,2485,2486],{},[21,2487],{"id":2488},"calibrate",[25,2490,2492],{"id":2491},"schaal-rotatie-en-positie-instellen","Schaal, rotatie en positie instellen",[10,2494,2495,2496,2499,2500,2499,2503,2506,2507,2509,2510,2512,2513,2516],{},"De lagenwerkbank heeft de stappen ",[14,2497,2498],{},"Bijsnijden",", ",[14,2501,2502],{},"Draaien",[14,2504,2505],{},"Schaal"," en ",[14,2508,108],{},". Tijdens het instellen blijven pannen en zoomen beschikbaar, maar tekengereedschappen zijn vergrendeld. Uw wijzigingen zijn een concept tot u ",[14,2511,78],{}," kiest; ",[14,2514,2515],{},"Annuleren"," verwerpt ze.",[10,2518,2519],{},"Kalibreer een afbeeldings- of PDF-laag met een bekende maat:",[37,2521,2522,2532,2535,2538,2541],{},[40,2523,2524,2525,2527,2528,2531],{},"Open ",[14,2526,2505],{}," of kies ",[14,2529,2530],{},"Kalibreren"," in de werkbalk.",[40,2533,2534],{},"Zet twee punten op een afstand waarvan u de werkelijke lengte kent.",[40,2536,2537],{},"Voer de lengte in meter in en controleer de preview.",[40,2539,2540],{},"Richt de referentielijn indien nodig horizontaal of verticaal uit.",[40,2542,2543,2544,155],{},"Bevestig pas na controle met ",[14,2545,78],{},[10,2547,2548],{},"Bij een DXF neemt PlanElec de schaal eerst uit de tekeneenheid over of toont het een schatting om te kiezen. De bron van de schaal blijft zichtbaar. Kalibreer handmatig na wanneer een bekende maat niet klopt.",[25,2550,2552],{"id":2551},"op-de-referentie-verder-tekenen","Op de referentie verder tekenen",[10,2554,2555],{},"Pas zo nodig dekking en uitsnede aan. Teken vervolgens gesloten buiten- en binnenmuren als polygoon of rechthoek. PlanElec herkent daaruit ruimtes; toestellen en kabelroutes baseren zich op deze bewerkbare muurstructuur, niet op pixels van de referentie.",[10,2557,2558],{},"Controleer vóór u verder plant:",[102,2560,2561,2564,2567,2570],{},[40,2562,2563],{},"Kloppen een of meer bekende maten met de ingestelde schaal?",[40,2565,2566],{},"Staat het plan goed gedraaid en op de juiste plaats?",[40,2568,2569],{},"Zijn alleen relevante lagen zichtbaar?",[40,2571,2572],{},"Zijn buiten- en binnenmuren als PlanElec-muren overgetekend?",[10,2574,2575],{},"Bij meerdere verdiepingen stelt u elke verdieping afzonderlijk in. Uitlijning tussen verdiepingen is een aparte stap en vervangt de kalibratie van een geïmporteerde laag niet.",[25,2577,2579],{"id":2578},"wat-importeren-niet-doet","Wat importeren niet doet",[10,2581,2582],{},"De import herkent geen ruimtes of elektrische installatie automatisch en maakt geen officiële opmeting. Het is een nauwkeurig tekenhulpmiddel. Controleer maten, muurverloop en de werkelijke uitvoering vóór u symbolen plaatst of documenten exporteert.",[10,2584,150,2585,155],{},[21,2586,2588],{"href":2587},"\u002Fhelp\u002Felektrische-symbolen-plaatsen-en-verbinden","elektrische symbolen plaatsen en met de topologie verbinden",{"title":157,"searchDepth":158,"depth":158,"links":2590},[2591,2592,2593,2594],{"id":2450,"depth":158,"text":2451},{"id":2491,"depth":158,"text":2492},{"id":2551,"depth":158,"text":2552},{"id":2578,"depth":158,"text":2579},"Gebruik een afbeelding, PDF of DXF als schaalvaste referentie, richt de laag uit en teken er het bewerkbare grondplan op.","floorplan-import-calibration",{},5,"\u002Fhelp\u002Ffloorplan-import-calibration.nl",{"title":2433,"description":2595},"grondplan-importeren-en-kalibreren","help\u002Ffloorplan-import-calibration.nl",[2604,2605,2606,2607,2608,2609],"grondplan importeren","PDF","DXF","kalibreren","schaal","lagenwerkbank","GyLdedrWi1NV2O0_zDOEK7JKL7-pusEHFnJtj2PtB8s",{"id":4,"title":5,"body":2612,"category":164,"description":165,"extension":166,"guideId":167,"locale":168,"meta":2710,"navigation":170,"order":171,"path":172,"publishedAt":173,"readTime":174,"seo":2711,"slug":176,"stem":177,"tags":2712,"updatedAt":173,"__hash__":185},{"type":7,"value":2613,"toc":2704},[2614,2618,2622,2624,2628,2638,2640,2642,2648,2654,2656,2660,2662,2664,2666,2668,2686,2688,2690,2700],[10,2615,12,2616,17],{},[14,2617,16],{},[10,2619,2620],{},[21,2621],{"id":23},[25,2623,28],{"id":27},[10,2625,31,2626,35],{},[14,2627,34],{},[37,2629,2630,2632,2634,2636],{},[40,2631,42],{},[40,2633,45],{},[40,2635,48],{},[40,2637,51],{},[10,2639,54],{},[25,2641,58],{"id":57},[10,2643,61,2644,65,2646,68],{},[14,2645,64],{},[14,2647,64],{},[10,2649,71,2650,75,2652,79],{},[14,2651,74],{},[14,2653,78],{},[10,2655,82],{},[10,2657,2658],{},[21,2659],{"id":87},[25,2661,91],{"id":90},[10,2663,94],{},[10,2665,97],{},[10,2667,100],{},[102,2669,2670,2674,2678,2682],{},[40,2671,2672,109],{},[14,2673,108],{},[40,2675,2676,114],{},[14,2677,74],{},[40,2679,2680,120],{},[14,2681,119],{},[40,2683,2684,126],{},[14,2685,125],{},[10,2687,129],{},[25,2689,133],{"id":132},[102,2691,2692,2694,2696,2698],{},[40,2693,138],{},[40,2695,141],{},[40,2697,144],{},[40,2699,147],{},[10,2701,150,2702,155],{},[21,2703,154],{"href":153},{"title":157,"searchDepth":158,"depth":158,"links":2705},[2706,2707,2708,2709],{"id":27,"depth":158,"text":28},{"id":57,"depth":158,"text":58},{"id":90,"depth":158,"text":91},{"id":132,"depth":158,"text":133},{},{"title":5,"description":165},[179,180,181,182,183,184],{"id":2714,"title":2715,"body":2716,"category":1291,"description":2833,"extension":166,"guideId":2834,"locale":168,"meta":2835,"navigation":170,"order":2836,"path":2837,"publishedAt":173,"readTime":1295,"seo":2838,"slug":2839,"stem":2840,"tags":2841,"updatedAt":173,"__hash__":2846},"help\u002Fhelp\u002Fswitch-chains-circuits-cable-routes.nl.md","Schakelketens, stroomkringen en kabelroutes bewerken",{"type":7,"value":2717,"toc":2827},[2718,2732,2737,2741,2748,2751,2754,2758,2762,2771,2774,2777,2782,2786,2800,2803,2806,2810,2824],[10,2719,2720,2721,2724,2725,2724,2728,2731],{},"Deze drie gereedschappen beantwoorden andere vragen: ",[14,2722,2723],{},"welke schakelaar bedient welk lichtpunt?"," ",[14,2726,2727],{},"Welke stroomkring voedt welk toestel?",[14,2729,2730],{},"Waar loopt de kabel ruimtelijk?"," Bewerk ze na elkaar zodat het plan technisch traceerbaar blijft.",[10,2733,2734],{},[21,2735],{"id":2736},"switch-chains",[25,2738,2740],{"id":2739},"schakelaars-en-lichtpunten-als-keten-verbinden","Schakelaars en lichtpunten als keten verbinden",[10,2742,2743,2744,2747],{},"Kies in het grondplan ",[14,2745,2746],{},"Schakelketen",". Dit gereedschap verbindt schakelaars en de lichtpunten die zij bedienen in een logische volgorde. Voor vrije schakelaars en lichtpunten in een ruimte kan PlanElec een voorstel maken; controleer het altijd tegen de bedoelde bediening.",[10,2749,2750],{},"Bij een manuele keten kiest u de betrokken toestellen bewust. Een geldige keten bevat minstens één schakelaar en één lichtpunt. Een toestel kan niet tegelijk in meerdere schakelketens zitten. Over verschillende verdiepingen blijft de keten projectbreed verbonden; per verdieping ziet u alleen de lokale delen en vervolgmarkeringen.",[10,2752,2753],{},"Schakelfunctie en poolaantal zijn verschillende instellingen. De toepassing kan een enkelpolige, wissel- of kruisschakeling uit de keten afleiden; het poolaantal kiest u uitdrukkelijk. Een serieschakelaar is één fysiek toestel met twee aparte kanalen: wijs elk lichtpunt bewust aan kanaal A of B toe.",[10,2755,2756],{},[21,2757],{"id":1143},[25,2759,2761],{"id":2760},"toestellen-aan-een-bestaande-stroomkring-toewijzen","Toestellen aan een bestaande stroomkring toewijzen",[10,2763,2474,2764,2767,2768,2770],{},[14,2765,2766],{},"Stroomkring toewijzen",". Selecteer in het paneel eerst de doelstroomkring of automaat en daarna de toestellen, eventueel via de verdiepingskeuze. Met ",[14,2769,78],{}," neemt PlanElec de selectie samen over.",[10,2772,2773],{},"Nog niet gekoppelde toestellen worden daarbij als verbruikers onder de gekozen automaat aangemaakt en met hun grondsymbool verbonden. Voor een toestel dat al aan een andere automaat hangt, vraagt de toepassing eerst een uitdrukkelijke bevestiging. Annuleren wijzigt geen projectdata; u kunt de volledige bevestiging in één stap ongedaan maken.",[10,2775,2776],{},"De stroomkringtoewijzing beschrijft de elektrische verbondenheid. Zij bepaalt nog geen werkelijk traject door muren, schachten of verdiepingen.",[10,2778,2779],{},[21,2780],{"id":2781},"cable-routes",[25,2783,2785],{"id":2784},"kabelroute-plannen-en-bijwerken","Kabelroute plannen en bijwerken",[10,2787,2474,2788,2791,2792,2795,2796,2799],{},[14,2789,2790],{},"Kabelroute",". Als kabels in de topologie bestaan, kunt u voor de actieve verdieping ",[14,2793,2794],{},"Alles automatisch routeren"," gebruiken of, na selectie van één kabel, ",[14,2797,2798],{},"Automatisch routeren",". De automatische route volgt zo veel mogelijk de getekende muren; toets die aan de beoogde uitvoering.",[10,2801,2802],{},"Selecteer een kabellijn om manueel te bewerken. Klik op een segment om een routepunt toe te voegen en meteen te verslepen; dubbelklik om een routepunt te verwijderen. Escape heft de selectie op of verlaat de modus. De getoonde lengte wordt gebruikt in materiaallijsten, spanningsvalberekening en exporten, dus controleer elk uitzonderlijk traject.",[10,2804,2805],{},"Voor een kabel tussen verdiepingen kiest u in het kabelroutepaneel uitdrukkelijk een bestaande trap, schacht of stijgweg. PlanElec verzint geen verticale verbinding. Ontbreekt een nodige verbinding of betrouwbare hoogte, dan blijft de route onvolledig in plaats van een schijnlengte te tonen.",[25,2807,2809],{"id":2808},"eindcontrole","Eindcontrole",[102,2811,2812,2815,2818,2821],{},[40,2813,2814],{},"Controleer de schakelketen op de gewenste bediening, niet alleen op nabijheid.",[40,2816,2817],{},"Controleer stroomkring, beveiliging en topologie van elk toestel.",[40,2819,2820],{},"Controleer kabelroute en lengte aan de geplande installatieweg.",[40,2822,2823],{},"Behandel automatische voorstellen als bewerkbare planhulp, niet als uitvoeringsvrijgave.",[10,2825,2826],{},"Daarna kunt u verdeelkast en eendraadschema verder controleren en de ondersteunde zelfcontrole uitvoeren.",{"title":157,"searchDepth":158,"depth":158,"links":2828},[2829,2830,2831,2832],{"id":2739,"depth":158,"text":2740},{"id":2760,"depth":158,"text":2761},{"id":2784,"depth":158,"text":2785},{"id":2808,"depth":158,"text":2809},"Houd lichtbediening, stroomkringtoewijzing en het fysieke kabeltraject apart en gebruik voor elke stap het juiste gereedschap.","switch-chains-circuits-cable-routes",{},7,"\u002Fhelp\u002Fswitch-chains-circuits-cable-routes.nl",{"title":2715,"description":2833},"schakelketens-stroomkringen-en-kabelroutes","help\u002Fswitch-chains-circuits-cable-routes.nl",[2842,2843,1302,2844,1301,2845],"schakelketen","wisselschakeling","automaat","kabellengte","y2npmArx1kUa99KSZHmFwkSOO1M3Kzsit2DwSTPUUGg",1787506471855]