[{"data":1,"prerenderedAt":1147},["ShallowReactive",2],{"blog-post-nl-stopcontacten-per-circuit":3,"blog-alternates-sockets-per-circuit":275},{"id":4,"title":5,"articleId":6,"body":7,"category":246,"date":247,"description":248,"extension":249,"lastUpdated":247,"locale":250,"meta":251,"navigation":252,"path":253,"publishDate":247,"readTime":254,"refreshInterval":255,"seo":256,"slug":257,"stem":258,"tags":259,"__hash__":274},"blog\u002Fblog\u002Fsockets-per-circuit.nl.md","Hoeveel stopcontacten per stroomkring? (AREI-limieten)","sockets-per-circuit",{"type":8,"value":9,"toc":236},"minimark",[10,15,32,36,93,97,158,162,165,187,200,204,211,215,230],[11,12,14],"h2",{"id":13},"maximaal-8-punten-per-stroomkring","Maximaal 8 punten per stroomkring",[16,17,18,19,23,24,27,28,31],"p",{},"Het AREI bepaalt in ",[20,21,22],"strong",{},"Art. 5.3.5.2b",": per eindkring mogen maximaal ",[20,25,26],{},"8 enkel- of meervoudige stopcontacten"," worden geïnstalleerd. Daarbij geldt een belangrijke telregel — een dubbel stopcontact telt als ",[20,29,30],{},"één"," punt, niet als twee.",[11,33,35],{"id":34},"telregels-in-detail","Telregels in detail",[37,38,39,52],"table",{},[40,41,42],"thead",{},[43,44,45,49],"tr",{},[46,47,48],"th",{},"Aansluiting",[46,50,51],{},"Telt als",[53,54,55,64,71,78,85],"tbody",{},[43,56,57,61],{},[58,59,60],"td",{},"Enkelvoudig stopcontact",[58,62,63],{},"1 punt",[43,65,66,69],{},[58,67,68],{},"Dubbel stopcontact",[58,70,63],{},[43,72,73,76],{},[58,74,75],{},"Drievoudig stopcontact",[58,77,63],{},[43,79,80,83],{},[58,81,82],{},"Lichtpunt",[58,84,63],{},[43,86,87,90],{},[58,88,89],{},"Vaste aansluiting (oven, kookplaat)",[58,91,92],{},"Eigen kring",[11,94,96],{"id":95},"kabel-en-automaat-per-type-stroomkring","Kabel en automaat per type stroomkring",[37,98,99,115],{},[40,100,101],{},[43,102,103,106,109,112],{},[46,104,105],{},"Type stroomkring",[46,107,108],{},"Kabel",[46,110,111],{},"Automaat",[46,113,114],{},"Max. punten",[53,116,117,131,144],{},[43,118,119,122,125,128],{},[58,120,121],{},"Stopcontacten",[58,123,124],{},"XVB 3G2,5",[58,126,127],{},"16A of 20A",[58,129,130],{},"8",[43,132,133,136,139,142],{},[58,134,135],{},"Verlichting",[58,137,138],{},"XVB 3G1,5",[58,140,141],{},"10A of 16A",[58,143,130],{},[43,145,146,149,152,155],{},[58,147,148],{},"Dedicated (oven)",[58,150,151],{},"XVB 3G4 of 3G6",[58,153,154],{},"20A of 32A",[58,156,157],{},"1",[11,159,161],{"id":160},"praktijkvoorbeeld-typische-eengezinswoning","Praktijkvoorbeeld: typische eengezinswoning",[16,163,164],{},"Een eengezinswoning met 3 slaapkamers, keuken, badkamer en woonkamer heeft doorgaans nodig:",[166,167,168,175,181],"ul",{},[169,170,171,174],"li",{},[20,172,173],{},"5–7 stopcontactkringen"," (leefruimtes, keuken, slaapkamers)",[169,176,177,180],{},[20,178,179],{},"3–4 verlichtingskringen"," (gelijkvloers, verdieping, buitenverlichting)",[169,182,183,186],{},[20,184,185],{},"3–4 dedicated kringen"," (oven, kookplaat, vaatwasser, droogkast)",[188,189,190],"blockquote",{},[16,191,192,195,196,199],{},[20,193,194],{},"Let op",": Keukens hebben vaak eigen dedicated stroomkringen nodig voor de vaatwasser, oven en kookplaat. Deze toestellen worden vast aangesloten en tellen ",[20,197,198],{},"niet"," als gewone stopcontacten — elk krijgt een eigen kring met een zwaardere kabel en een passende automaat.",[11,201,203],{"id":202},"bestaande-installaties-arei-deel-8","Bestaande installaties (AREI Deel 8)",[16,205,206,207,210],{},"Bij bestaande installaties die vóór het huidige AREI zijn aangelegd, staat ",[20,208,209],{},"Deel 8"," onder bepaalde voorwaarden meer dan 8 punten per stroomkring toe — op voorwaarde dat de totale belasting redelijk blijft en de kabeldoorsnede voldoende gedimensioneerd is. Bij renovatie of uitbreiding gelden echter de huidige limieten.",[11,212,214],{"id":213},"gerelateerde-artikelen","Gerelateerde artikelen",[166,216,217,224],{},[169,218,219],{},[220,221,223],"a",{"href":222},"\u002Fblog\u002F30ma-aardlek-per-stopcontact","Heb ik een 30mA differentieel nodig per stopcontact?",[169,225,226],{},[220,227,229],{"href":228},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België — wat u moet weten",[16,231,232],{},[220,233,235],{"href":234},"\u002F","Maak nu uw AREI-conform eendraadschema — gratis →",{"title":237,"searchDepth":238,"depth":238,"links":239},"",2,[240,241,242,243,244,245],{"id":13,"depth":238,"text":14},{"id":34,"depth":238,"text":35},{"id":95,"depth":238,"text":96},{"id":160,"depth":238,"text":161},{"id":202,"depth":238,"text":203},{"id":213,"depth":238,"text":214},"faq","2026-03-11","Maximaal 8 punten per stroomkring — maar hoe tel je correct? Ontdek de AREI-regels voor stopcontacten, verlichting en dedicated kringen.","md","nl",{},true,"\u002Fblog\u002Fsockets-per-circuit.nl","3 min",12,{"title":5,"description":248},"stopcontacten-per-circuit","blog\u002Fsockets-per-circuit.nl",[260,261,262,263,264,265,266,267,268,269,270,271,272,273],"AREI","RGIE","stopcontact","stroomkring","automaat","kabel","XVB","eendraadschema","keuring","elektrische installatie","België","Eindrahtschema","schéma unifilaire","situatieschema","BuWg7G13rYSMPY3BvaGO6593YnVaDNke8eA_EF8Yhw0",[276,512,749,983],{"id":277,"title":278,"articleId":6,"body":279,"category":246,"date":247,"description":495,"extension":249,"lastUpdated":247,"locale":496,"meta":497,"navigation":252,"path":498,"publishDate":247,"readTime":254,"refreshInterval":255,"seo":499,"slug":500,"stem":501,"tags":502,"__hash__":511},"blog\u002Fblog\u002Fsockets-per-circuit.de.md","Wie viele Steckdosen pro Stromkreis? (AREI-Grenzwerte)",{"type":8,"value":280,"toc":487},[281,285,299,303,354,358,414,418,421,441,453,457,464,468,482],[11,282,284],{"id":283},"maximal-8-punkte-pro-stromkreis","Maximal 8 Punkte pro Stromkreis",[16,286,287,288,290,291,294,295,298],{},"Das AREI legt in ",[20,289,22],{}," fest: Pro Endstromkreis dürfen maximal ",[20,292,293],{},"8 Einzel- oder Mehrfachsteckdosen"," installiert werden. Dabei gilt eine wichtige Zählregel — eine Doppelsteckdose zählt als ",[20,296,297],{},"ein"," Punkt, nicht als zwei.",[11,300,302],{"id":301},"zählregeln-im-detail","Zählregeln im Detail",[37,304,305,315],{},[40,306,307],{},[43,308,309,312],{},[46,310,311],{},"Anschluss",[46,313,314],{},"Zählt als",[53,316,317,325,332,339,346],{},[43,318,319,322],{},[58,320,321],{},"Einfachsteckdose",[58,323,324],{},"1 Punkt",[43,326,327,330],{},[58,328,329],{},"Doppelsteckdose",[58,331,324],{},[43,333,334,337],{},[58,335,336],{},"Dreifachsteckdose",[58,338,324],{},[43,340,341,344],{},[58,342,343],{},"Lichtauslass",[58,345,324],{},[43,347,348,351],{},[58,349,350],{},"Festanschluss (Herd, Backofen)",[58,352,353],{},"Eigener Stromkreis",[11,355,357],{"id":356},"kabel-und-sicherung-pro-stromkreis-typ","Kabel und Sicherung pro Stromkreis-Typ",[37,359,360,375],{},[40,361,362],{},[43,363,364,367,369,372],{},[46,365,366],{},"Stromkreis-Typ",[46,368,108],{},[46,370,371],{},"Sicherung",[46,373,374],{},"Max. Punkte",[53,376,377,389,401],{},[43,378,379,382,384,387],{},[58,380,381],{},"Steckdosen",[58,383,124],{},[58,385,386],{},"16A oder 20A",[58,388,130],{},[43,390,391,394,396,399],{},[58,392,393],{},"Beleuchtung",[58,395,138],{},[58,397,398],{},"10A oder 16A",[58,400,130],{},[43,402,403,406,409,412],{},[58,404,405],{},"Dediziert (Herd)",[58,407,408],{},"XVB 3G4 → 25A, XVB 3G6 → 32A",[58,410,411],{},"25A oder 32A",[58,413,157],{},[11,415,417],{"id":416},"praxisbeispiel-typisches-einfamilienhaus","Praxisbeispiel: Typisches Einfamilienhaus",[16,419,420],{},"Ein Einfamilienhaus mit 3 Schlafzimmern, Küche, Bad und Wohnzimmer braucht typischerweise:",[166,422,423,429,435],{},[169,424,425,428],{},[20,426,427],{},"5–7 Steckdosen-Stromkreise"," (Wohnräume, Küche, Schlafzimmer)",[169,430,431,434],{},[20,432,433],{},"3–4 Lichtstromkreise"," (Erdgeschoss, Obergeschoss, Außenbeleuchtung)",[169,436,437,440],{},[20,438,439],{},"3–4 dedizierte Stromkreise"," (Backofen, Kochfeld, Spülmaschine, Trockner)",[188,442,443],{},[16,444,445,448,449,452],{},[20,446,447],{},"Achtung",": Küchen brauchen oft eigene dedizierte Stromkreise für Spülmaschine, Backofen und Kochfeld. Diese Geräte werden fest angeschlossen und zählen ",[20,450,451],{},"nicht"," als normale Steckdose — sie erhalten jeweils einen eigenen Stromkreis mit stärkerem Kabel und passender Sicherung.",[11,454,456],{"id":455},"altbau-regelung-arei-part-8","Altbau-Regelung (AREI Part 8)",[16,458,459,460,463],{},"Bei Bestandsanlagen, die vor dem aktuellen AREI errichtet wurden, erlaubt ",[20,461,462],{},"Part 8"," unter bestimmten Bedingungen mehr als 8 Punkte pro Stromkreis — vorausgesetzt, die Gesamtbelastung bleibt vertretbar und der Kabelquerschnitt ist ausreichend dimensioniert. Bei einer Renovierung oder Erweiterung gelten jedoch die aktuellen Grenzwerte.",[11,465,467],{"id":466},"verwandte-artikel","Verwandte Artikel",[166,469,470,476],{},[169,471,472],{},[220,473,475],{"href":474},"\u002Fde\u002Fblog\u002F30ma-fi-pro-steckdose","Brauche ich einen 30mA FI-Schalter für jede Steckdose?",[169,477,478],{},[220,479,481],{"href":480},"\u002Fde\u002Fblog\u002Felektrische-abnahme","Elektrische Abnahme in Belgien — was Sie wissen müssen",[16,483,484],{},[220,485,486],{"href":234},"Erstellen Sie jetzt Ihr AREI-konformes Eindrahtschema — kostenlos →",{"title":237,"searchDepth":238,"depth":238,"links":488},[489,490,491,492,493,494],{"id":283,"depth":238,"text":284},{"id":301,"depth":238,"text":302},{"id":356,"depth":238,"text":357},{"id":416,"depth":238,"text":417},{"id":455,"depth":238,"text":456},{"id":466,"depth":238,"text":467},"Maximal 8 Punkte pro Stromkreis — aber wie zählt man richtig? Erfahren Sie die AREI-Regeln für Steckdosen, Beleuchtung und dedizierte Stromkreise.","de",{},"\u002Fblog\u002Fsockets-per-circuit.de",{"title":278,"description":495},"steckdosen-pro-stromkreis","blog\u002Fsockets-per-circuit.de",[260,261,503,504,371,108,266,271,505,506,507,508,509,272,510],"Steckdose","Stromkreis","Eendraadschema","Stromabnahme","Keuring","elektrische Installation","Belgien","Situationsplan","z2g7vvhEZpHUUqR3P13C2pKL9huebIaeHq-9BMYLZk0",{"id":513,"title":514,"articleId":6,"body":515,"category":246,"date":247,"description":732,"extension":249,"lastUpdated":247,"locale":733,"meta":734,"navigation":252,"path":735,"publishDate":247,"readTime":254,"refreshInterval":255,"seo":736,"slug":6,"stem":737,"tags":738,"__hash__":748},"blog\u002Fblog\u002Fsockets-per-circuit.en.md","How Many Sockets Per Circuit? (AREI Limits)",{"type":8,"value":516,"toc":724},[517,521,535,539,590,594,652,656,659,679,691,695,701,705,719],[11,518,520],{"id":519},"maximum-8-points-per-circuit","Maximum 8 points per circuit",[16,522,523,524,526,527,530,531,534],{},"The AREI specifies in ",[20,525,22],{},": a maximum of ",[20,528,529],{},"8 single or multiple socket outlets"," may be installed per final circuit. An important counting rule applies — a double socket counts as ",[20,532,533],{},"one"," point, not two.",[11,536,538],{"id":537},"counting-rules-in-detail","Counting rules in detail",[37,540,541,551],{},[40,542,543],{},[43,544,545,548],{},[46,546,547],{},"Connection",[46,549,550],{},"Counts as",[53,552,553,561,568,575,582],{},[43,554,555,558],{},[58,556,557],{},"Single socket",[58,559,560],{},"1 point",[43,562,563,566],{},[58,564,565],{},"Double socket",[58,567,560],{},[43,569,570,573],{},[58,571,572],{},"Triple socket",[58,574,560],{},[43,576,577,580],{},[58,578,579],{},"Light outlet",[58,581,560],{},[43,583,584,587],{},[58,585,586],{},"Fixed connection (oven, hob)",[58,588,589],{},"Dedicated circuit",[11,591,593],{"id":592},"cable-and-breaker-per-circuit-type","Cable and breaker per circuit type",[37,595,596,612],{},[40,597,598],{},[43,599,600,603,606,609],{},[46,601,602],{},"Circuit type",[46,604,605],{},"Cable",[46,607,608],{},"Breaker",[46,610,611],{},"Max. points",[53,613,614,627,640],{},[43,615,616,619,622,625],{},[58,617,618],{},"Sockets",[58,620,621],{},"XVB 3G2.5",[58,623,624],{},"16A or 20A",[58,626,130],{},[43,628,629,632,635,638],{},[58,630,631],{},"Lighting",[58,633,634],{},"XVB 3G1.5",[58,636,637],{},"10A or 16A",[58,639,130],{},[43,641,642,644,647,650],{},[58,643,148],{},[58,645,646],{},"XVB 3G4 or 3G6",[58,648,649],{},"20A or 32A",[58,651,157],{},[11,653,655],{"id":654},"practical-example-typical-single-family-home","Practical example: typical single-family home",[16,657,658],{},"A single-family home with 3 bedrooms, kitchen, bathroom, and living room typically requires:",[166,660,661,667,673],{},[169,662,663,666],{},[20,664,665],{},"5–7 socket circuits"," (living areas, kitchen, bedrooms)",[169,668,669,672],{},[20,670,671],{},"3–4 lighting circuits"," (ground floor, upper floor, outdoor lighting)",[169,674,675,678],{},[20,676,677],{},"3–4 dedicated circuits"," (oven, hob, dishwasher, dryer)",[188,680,681],{},[16,682,683,686,687,690],{},[20,684,685],{},"Warning",": Kitchens often need dedicated circuits for the dishwasher, oven, and hob. These appliances are hardwired and do ",[20,688,689],{},"not"," count as regular sockets — each gets its own circuit with heavier cable and an appropriately rated breaker.",[11,692,694],{"id":693},"existing-installations-arei-part-8","Existing installations (AREI Part 8)",[16,696,697,698,700],{},"For existing installations built before the current AREI, ",[20,699,462],{}," allows more than 8 points per circuit under certain conditions — provided the total load remains reasonable and the cable cross-section is adequately sized. However, when renovating or extending, the current limits apply.",[11,702,704],{"id":703},"related-articles","Related articles",[166,706,707,713],{},[169,708,709],{},[220,710,712],{"href":711},"\u002Fen\u002Fblog\u002F30ma-rcd-per-socket","Do I need a 30mA RCD for every socket?",[169,714,715],{},[220,716,718],{"href":717},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical inspection in Belgium — what you need to know",[16,720,721],{},[220,722,723],{"href":234},"Create your AREI-compliant single-line diagram now — free →",{"title":237,"searchDepth":238,"depth":238,"links":725},[726,727,728,729,730,731],{"id":519,"depth":238,"text":520},{"id":537,"depth":238,"text":538},{"id":592,"depth":238,"text":593},{"id":654,"depth":238,"text":655},{"id":693,"depth":238,"text":694},{"id":703,"depth":238,"text":704},"Maximum 8 points per circuit — but how do you count correctly? Learn the AREI rules for sockets, lighting, and dedicated circuits.","en",{},"\u002Fblog\u002Fsockets-per-circuit.en",{"title":514,"description":732},"blog\u002Fsockets-per-circuit.en",[260,261,739,740,741,742,266,743,267,271,272,744,268,745,746,747],"socket","circuit","breaker","cable","single-line diagram","inspection","electrical installation","Belgium","situation plan","mwp_PStl1s1BARAI_qBJqAJMDLGOsZKXOSTAEvhXUOg",{"id":750,"title":751,"articleId":6,"body":752,"category":246,"date":247,"description":967,"extension":249,"lastUpdated":247,"locale":968,"meta":969,"navigation":252,"path":970,"publishDate":247,"readTime":254,"refreshInterval":255,"seo":971,"slug":972,"stem":973,"tags":974,"__hash__":982},"blog\u002Fblog\u002Fsockets-per-circuit.fr.md","Combien de prises par circuit ? (Limites RGIE)",{"type":8,"value":753,"toc":959},[754,758,772,776,826,830,886,890,893,913,925,929,936,940,954],[11,755,757],{"id":756},"maximum-8-points-par-circuit","Maximum 8 points par circuit",[16,759,760,761,763,764,767,768,771],{},"Le RGIE stipule à l'",[20,762,22],{}," : un maximum de ",[20,765,766],{},"8 prises simples ou multiples"," peut être installé par circuit terminal. Une règle de comptage importante s'applique — une prise double compte comme ",[20,769,770],{},"un"," seul point, pas deux.",[11,773,775],{"id":774},"règles-de-comptage-en-détail","Règles de comptage en détail",[37,777,778,788],{},[40,779,780],{},[43,781,782,785],{},[46,783,784],{},"Raccordement",[46,786,787],{},"Compte comme",[53,789,790,797,804,811,818],{},[43,791,792,795],{},[58,793,794],{},"Prise simple",[58,796,560],{},[43,798,799,802],{},[58,800,801],{},"Prise double",[58,803,560],{},[43,805,806,809],{},[58,807,808],{},"Prise triple",[58,810,560],{},[43,812,813,816],{},[58,814,815],{},"Point lumineux",[58,817,560],{},[43,819,820,823],{},[58,821,822],{},"Raccordement fixe (four, taque)",[58,824,825],{},"Circuit dédié",[11,827,829],{"id":828},"câble-et-disjoncteur-par-type-de-circuit","Câble et disjoncteur par type de circuit",[37,831,832,847],{},[40,833,834],{},[43,835,836,839,842,845],{},[46,837,838],{},"Type de circuit",[46,840,841],{},"Câble",[46,843,844],{},"Disjoncteur",[46,846,611],{},[53,848,849,861,873],{},[43,850,851,854,856,859],{},[58,852,853],{},"Prises",[58,855,124],{},[58,857,858],{},"16A ou 20A",[58,860,130],{},[43,862,863,866,868,871],{},[58,864,865],{},"Éclairage",[58,867,138],{},[58,869,870],{},"10A ou 16A",[58,872,130],{},[43,874,875,878,881,884],{},[58,876,877],{},"Dédié (four)",[58,879,880],{},"XVB 3G4 ou 3G6",[58,882,883],{},"20A ou 32A",[58,885,157],{},[11,887,889],{"id":888},"exemple-pratique-maison-unifamiliale-typique","Exemple pratique : maison unifamiliale typique",[16,891,892],{},"Une maison unifamiliale avec 3 chambres, cuisine, salle de bain et salon nécessite généralement :",[166,894,895,901,907],{},[169,896,897,900],{},[20,898,899],{},"5 à 7 circuits prises"," (pièces de vie, cuisine, chambres)",[169,902,903,906],{},[20,904,905],{},"3 à 4 circuits éclairage"," (rez-de-chaussée, étage, éclairage extérieur)",[169,908,909,912],{},[20,910,911],{},"3 à 4 circuits dédiés"," (four, taque de cuisson, lave-vaisselle, sèche-linge)",[188,914,915],{},[16,916,917,920,921,924],{},[20,918,919],{},"Attention"," : Les cuisines nécessitent souvent des circuits dédiés pour le lave-vaisselle, le four et la taque de cuisson. Ces appareils sont raccordés en fixe et ne comptent ",[20,922,923],{},"pas"," comme des prises normales — chacun dispose de son propre circuit avec un câble plus fort et un disjoncteur adapté.",[11,926,928],{"id":927},"installations-existantes-rgie-partie-8","Installations existantes (RGIE Partie 8)",[16,930,931,932,935],{},"Pour les installations existantes construites avant le RGIE actuel, la ",[20,933,934],{},"Partie 8"," autorise plus de 8 points par circuit sous certaines conditions — à condition que la charge totale reste raisonnable et que la section du câble soit suffisamment dimensionnée. Toutefois, en cas de rénovation ou d'extension, les limites actuelles s'appliquent.",[11,937,939],{"id":938},"articles-connexes","Articles connexes",[166,941,942,948],{},[169,943,944],{},[220,945,947],{"href":946},"\u002Ffr\u002Fblog\u002F30ma-ddr-par-prise","Ai-je besoin d'un différentiel 30mA par prise ?",[169,949,950],{},[220,951,953],{"href":952},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique — ce qu'il faut savoir",[16,955,956],{},[220,957,958],{"href":234},"Créez votre schéma unifilaire conforme RGIE — gratuit →",{"title":237,"searchDepth":238,"depth":238,"links":960},[961,962,963,964,965,966],{"id":756,"depth":238,"text":757},{"id":774,"depth":238,"text":775},{"id":828,"depth":238,"text":829},{"id":888,"depth":238,"text":889},{"id":927,"depth":238,"text":928},{"id":938,"depth":238,"text":939},"Maximum 8 points par circuit — mais comment compter correctement ? Découvrez les règles du RGIE pour les prises, l'éclairage et les circuits dédiés.","fr",{},"\u002Fblog\u002Fsockets-per-circuit.fr",{"title":751,"description":967},"prises-par-circuit","blog\u002Fsockets-per-circuit.fr",[260,261,975,740,976,977,266,272,267,978,979,980,271,981],"prise","disjoncteur","câble","contrôle électrique","installation électrique","Belgique","plan de situation","IU-kGbBFs_8xwa1wbV4WIEStsLBZEjX__-wAl3TL-uQ",{"id":4,"title":5,"articleId":6,"body":984,"category":246,"date":247,"description":248,"extension":249,"lastUpdated":247,"locale":250,"meta":1144,"navigation":252,"path":253,"publishDate":247,"readTime":254,"refreshInterval":255,"seo":1145,"slug":257,"stem":258,"tags":1146,"__hash__":274},{"type":8,"value":985,"toc":1136},[986,988,996,998,1040,1042,1088,1090,1092,1106,1114,1116,1120,1122,1132],[11,987,14],{"id":13},[16,989,18,990,23,992,27,994,31],{},[20,991,22],{},[20,993,26],{},[20,995,30],{},[11,997,35],{"id":34},[37,999,1000,1008],{},[40,1001,1002],{},[43,1003,1004,1006],{},[46,1005,48],{},[46,1007,51],{},[53,1009,1010,1016,1022,1028,1034],{},[43,1011,1012,1014],{},[58,1013,60],{},[58,1015,63],{},[43,1017,1018,1020],{},[58,1019,68],{},[58,1021,63],{},[43,1023,1024,1026],{},[58,1025,75],{},[58,1027,63],{},[43,1029,1030,1032],{},[58,1031,82],{},[58,1033,63],{},[43,1035,1036,1038],{},[58,1037,89],{},[58,1039,92],{},[11,1041,96],{"id":95},[37,1043,1044,1056],{},[40,1045,1046],{},[43,1047,1048,1050,1052,1054],{},[46,1049,105],{},[46,1051,108],{},[46,1053,111],{},[46,1055,114],{},[53,1057,1058,1068,1078],{},[43,1059,1060,1062,1064,1066],{},[58,1061,121],{},[58,1063,124],{},[58,1065,127],{},[58,1067,130],{},[43,1069,1070,1072,1074,1076],{},[58,1071,135],{},[58,1073,138],{},[58,1075,141],{},[58,1077,130],{},[43,1079,1080,1082,1084,1086],{},[58,1081,148],{},[58,1083,151],{},[58,1085,154],{},[58,1087,157],{},[11,1089,161],{"id":160},[16,1091,164],{},[166,1093,1094,1098,1102],{},[169,1095,1096,174],{},[20,1097,173],{},[169,1099,1100,180],{},[20,1101,179],{},[169,1103,1104,186],{},[20,1105,185],{},[188,1107,1108],{},[16,1109,1110,195,1112,199],{},[20,1111,194],{},[20,1113,198],{},[11,1115,203],{"id":202},[16,1117,206,1118,210],{},[20,1119,209],{},[11,1121,214],{"id":213},[166,1123,1124,1128],{},[169,1125,1126],{},[220,1127,223],{"href":222},[169,1129,1130],{},[220,1131,229],{"href":228},[16,1133,1134],{},[220,1135,235],{"href":234},{"title":237,"searchDepth":238,"depth":238,"links":1137},[1138,1139,1140,1141,1142,1143],{"id":13,"depth":238,"text":14},{"id":34,"depth":238,"text":35},{"id":95,"depth":238,"text":96},{"id":160,"depth":238,"text":161},{"id":202,"depth":238,"text":203},{"id":213,"depth":238,"text":214},{},{"title":5,"description":248},[260,261,262,263,264,265,266,267,268,269,270,271,272,273],1775151660076]