[{"data":1,"prerenderedAt":1535},["ShallowReactive",2],{"blog-teaser-nl":3},[4,919,1226],{"id":5,"title":6,"articleId":7,"body":8,"category":898,"date":899,"description":900,"extension":901,"lastUpdated":899,"locale":902,"meta":903,"navigation":777,"path":904,"publishDate":899,"readTime":905,"refreshInterval":906,"seo":907,"slug":908,"stem":909,"tags":910,"__hash__":918},"blog\u002Fblog\u002Fdraw-situation-plan.nl.md","Situatieschema tekenen: Stap-voor-stap handleiding volgens AREI","draw-situation-plan",{"type":9,"value":10,"toc":876},"minimark",[11,15,24,42,45,48,53,58,61,66,91,95,98,208,210,214,225,404,412,414,418,421,425,457,461,482,486,507,511,514,538,542,562,564,568,575,580,592,597,611,628,630,634,637,663,665,669,760,762,766,834,836,840,861,863],[12,13,6],"h1",{"id":14},"situatieschema-tekenen-stap-voor-stap-handleiding-volgens-arei",[16,17,18,19,23],"p",{},"Het situatieschema (ook wel situatieplan of plan de situation) toont ",[20,21,22],"strong",{},"waar precies"," elk elektrisch onderdeel zich in uw gebouw bevindt. Samen met het éénlijnschema is het één van de twee verplichte documenten voor elke elektrische installatie in België — zonder situatieschema slaagt de keuring door het erkend controleorganisme niet.",[25,26,27],"blockquote",{},[16,28,29,32,33,37,38,41],{},[20,30,31],{},"Kort uitgelegd:"," Terwijl het éénlijnschema de ",[34,35,36],"em",{},"logische schakeling"," weergeeft (welke schakelaar bedient welk lichtpunt, via welk circuit), toont het situatieschema de ",[34,39,40],{},"fysieke positie"," van elk onderdeel op het grondplan.",[16,43,44],{},"In deze handleiding leert u hoe u stap voor stap een normconform situatieschema maakt.",[46,47],"hr",{},[49,50,52],"h2",{"id":51},"stap-1-grondplan-voorbereiden","Stap 1: Grondplan voorbereiden",[54,55,57],"h3",{"id":56},"afmetingen-en-schaal","Afmetingen en schaal",[16,59,60],{},"Het grondplan vormt de basis van uw situatieschema. U kunt het overnemen van een bouwplan of zelf tekenen.",[16,62,63],{},[20,64,65],{},"Belangrijk:",[67,68,69,77,84],"ul",{},[70,71,72,73,76],"li",{},"Gebruik een ",[20,74,75],{},"uniforme schaal"," (gebruikelijk: 1:50 of 1:100).",[70,78,79,80,83],{},"Teken alle ",[20,81,82],{},"muren, deuren en ramen"," in.",[70,85,86,87,90],{},"Markeer de ",[20,88,89],{},"openingsrichting"," van deuren (kwartcirkel) — dit beïnvloedt de schakelaarspositie.",[54,92,94],{"id":93},"ruimtes-labelen","Ruimtes labelen",[16,96,97],{},"Voorzie elke ruimte van een benaming en idealiter het oppervlak:",[99,100,101,117],"table",{},[102,103,104],"thead",{},[105,106,107,111,114],"tr",{},[108,109,110],"th",{},"Afkorting",[108,112,113],{},"Ruimte",[108,115,116],{},"Typisch oppervlak",[118,119,120,132,143,154,165,176,187,198],"tbody",{},[105,121,122,126,129],{},[123,124,125],"td",{},"WK",[123,127,128],{},"Woonkamer",[123,130,131],{},"25–40 m²",[105,133,134,137,140],{},[123,135,136],{},"KE",[123,138,139],{},"Keuken",[123,141,142],{},"10–20 m²",[105,144,145,148,151],{},[123,146,147],{},"SK",[123,149,150],{},"Slaapkamer",[123,152,153],{},"12–18 m²",[105,155,156,159,162],{},[123,157,158],{},"BK",[123,160,161],{},"Badkamer",[123,163,164],{},"5–10 m²",[105,166,167,170,173],{},[123,168,169],{},"HA",[123,171,172],{},"Hal\u002FGang",[123,174,175],{},"5–15 m²",[105,177,178,181,184],{},[123,179,180],{},"GA",[123,182,183],{},"Garage",[123,185,186],{},"15–30 m²",[105,188,189,192,195],{},[123,190,191],{},"KL",[123,193,194],{},"Kelder",[123,196,197],{},"variabel",[105,199,200,203,206],{},[123,201,202],{},"BU",[123,204,205],{},"Buitenzone",[123,207,197],{},[46,209],{},[49,211,213],{"id":212},"stap-2-arei-symbolen-gebruiken","Stap 2: AREI-symbolen gebruiken",[16,215,216,217,220,221,224],{},"Het AREI schrijft in ",[20,218,219],{},"Tabel 2.23"," precies voor welke symbolen gebruikt moeten worden. Deze zijn gebaseerd op de norm ",[20,222,223],{},"IEC 60617",". Hier de 10 belangrijkste symbolen voor het situatieschema:",[99,226,227,243],{},[102,228,229],{},[105,230,231,234,237,240],{},[108,232,233],{},"Nr.",[108,235,236],{},"Symbool",[108,238,239],{},"Beschrijving",[108,241,242],{},"Gebruik",[118,244,245,261,276,292,308,324,340,356,372,388],{},[105,246,247,250,253,258],{},[123,248,249],{},"1",[123,251,252],{},"⏚ Halve cirkel",[123,254,255],{},[20,256,257],{},"Enkel stopcontact",[123,259,260],{},"Wandpositie markeren",[105,262,263,266,269,274],{},[123,264,265],{},"2",[123,267,268],{},"⏚⏚ Dubbele halve cirkel",[123,270,271],{},[20,272,273],{},"Dubbel stopcontact",[123,275,260],{},[105,277,278,281,284,289],{},[123,279,280],{},"3",[123,282,283],{},"○ met kruis",[123,285,286],{},[20,287,288],{},"Plafondlamp",[123,290,291],{},"Midden van de ruimte\u002Fpositie",[105,293,294,297,300,305],{},[123,295,296],{},"4",[123,298,299],{},"─○ met streep",[123,301,302],{},[20,303,304],{},"Wandlamp",[123,306,307],{},"Aan de wand",[105,309,310,313,316,321],{},[123,311,312],{},"5",[123,314,315],{},"Schakelaarsteken",[123,317,318],{},[20,319,320],{},"Enkelpolige schakelaar",[123,322,323],{},"Naast de deur (openingszijde)",[105,325,326,329,332,337],{},[123,327,328],{},"6",[123,330,331],{},"Schakelaarsteken met 2 pijlen",[123,333,334],{},[20,335,336],{},"Serieschakelaar",[123,338,339],{},"Bedient 2 lichtpunten",[105,341,342,345,348,353],{},[123,343,344],{},"7",[123,346,347],{},"Schakelaarsteken met lijn",[123,349,350],{},[20,351,352],{},"Wisselschakelaar",[123,354,355],{},"Twee plaatsen, één licht",[105,357,358,361,364,369],{},[123,359,360],{},"8",[123,362,363],{},"Rechthoek met bliksem",[123,365,366],{},[20,367,368],{},"Verdeelkast",[123,370,371],{},"Meestal hal\u002Ftechnische ruimte",[105,373,374,377,380,385],{},[123,375,376],{},"9",[123,378,379],{},"⏚ met PE",[123,381,382],{},[20,383,384],{},"Aardingsaansluiting",[123,386,387],{},"Aardingspunt",[105,389,390,393,396,401],{},[123,391,392],{},"10",[123,394,395],{},"Cirkel met R",[123,397,398],{},[20,399,400],{},"Rookmelder",[123,402,403],{},"Elke slaapkamer, hal, trappenhuis",[25,405,406],{},[16,407,408,411],{},[20,409,410],{},"Tip:"," Gebruik uitsluitend de AREI-symbolen. Eigen verzonnen symbolen worden bij de keuring afgekeurd.",[46,413],{},[49,415,417],{"id":416},"stap-3-componenten-intekenen","Stap 3: Componenten intekenen",[16,419,420],{},"Nu plaatst u de symbolen op het grondplan. Volgende regels helpen bij de correcte positionering:",[54,422,424],{"id":423},"stopcontacten","Stopcontacten",[67,426,427,433,439,445,451],{},[70,428,429,432],{},[20,430,431],{},"Op de wand"," tekenen, op de werkelijke positie.",[70,434,435,438],{},[20,436,437],{},"Keuken:"," werkblad minstens 4 stopcontacten, waarvan 2 boven het werkblad. Aparte stopcontacten voor oven, vaatwasser, koelkast.",[70,440,441,444],{},[20,442,443],{},"Woonruimtes:"," Minstens 1 stopcontact per begonnen 4 m² (praktijkaanbeveling van de installateurverenigingen — het AREI schrijft geen minimumaantal stopcontacten per oppervlakte voor).",[70,446,447,450],{},[20,448,449],{},"Badkamer:"," Laagspanningsstopcontacten pas vanaf zone 2 (alleen bij badkuipen, met 30mA differentieel) of buiten de zones. Bij douches bestaat zone 2 niet (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[70,452,453,456],{},[20,454,455],{},"Buiten:"," Indien aanwezig, moet een buitenstopcontact weerbestendig zijn (IP44) en met eigen 30mA differentieel beveiligd zijn.",[54,458,460],{"id":459},"schakelaars","Schakelaars",[67,462,463,469,475],{},[70,464,465,468],{},[20,466,467],{},"Naast de deur"," aan de openingszijde, ca. 105 cm hoogte (praktijkaanbeveling — het AREI schrijft geen specifieke schakelaarhoogte voor, maar vereist wel 'gemakkelijk bereikbaar').",[70,470,471,474],{},[20,472,473],{},"Wisselschakelaars"," bij ruimtes met meerdere ingangen of aan het begin\u002Feinde van de trap.",[70,476,477,478,481],{},"Verbind schakelaars en bijbehorende lichtpunten met een ",[20,479,480],{},"stippellijn",".",[54,483,485],{"id":484},"verlichtingspunten","Verlichtingspunten",[67,487,488,494,500],{},[70,489,490,493],{},[20,491,492],{},"Plafondlampen"," in het midden van de ruimte of op de geplande positie.",[70,495,496,499],{},[20,497,498],{},"Wandlampen"," op de wandpositie.",[70,501,502,503,506],{},"Elke ruimte heeft minstens ",[20,504,505],{},"één lichtpunt"," nodig.",[54,508,510],{"id":509},"rookmelders","Rookmelders",[16,512,513],{},"Verplicht volgens de Belgische brandveiligheidswetgeving (regionaal verschillend):",[67,515,516,523,529,535],{},[70,517,518,519,522],{},"In ",[20,520,521],{},"Vlaanderen:"," Verplicht in vluchtwegen (gangen, trappenhuizen); in slaapkamers aanbevolen maar niet verplicht.",[70,524,518,525,528],{},[20,526,527],{},"Wallonië en Brussel"," gelden eigen regelingen.",[70,530,531,534],{},[20,532,533],{},"Gangen en trappenhuizen"," — minstens een rookmelder per verdieping.",[70,536,537],{},"In de keuken optioneel (hittemelder heeft de voorkeur wegens vals alarm).",[54,539,541],{"id":540},"speciale-verbruikers","Speciale verbruikers",[67,543,544,550,556],{},[70,545,546,549],{},[20,547,548],{},"Laadpaal"," (elektrisch voertuig): garage of buitenmuur, eigen circuit.",[70,551,552,555],{},[20,553,554],{},"Boiler\u002FDoorstromer:"," Eigen circuit, positie intekenen.",[70,557,558,561],{},[20,559,560],{},"Warmtepomp\u002FAirco:"," Buitenunit + binnenunit markeren.",[46,563],{},[49,565,567],{"id":566},"stap-4-circuitnummers-toewijzen","Stap 4: Circuitnummers toewijzen",[16,569,570,571,574],{},"Elk onderdeel in het situatieschema krijgt ",[20,572,573],{},"hetzelfde circuitnummer"," als in het éénlijnschema. Dit is essentieel voor de toewijzing bij de keuring.",[16,576,577],{},[20,578,579],{},"Zo werkt het:",[581,582,583,586,589],"ol",{},[70,584,585],{},"Nummer uw circuits in het éénlijnschema (1, 2, 3, ...).",[70,587,588],{},"Schrijf het nummer bij elk onderdeel in het situatieschema.",[70,590,591],{},"Gebruik een uniforme notatie: bijv. \"K1\" voor kring 1 of gewoon \"1\".",[16,593,594],{},[20,595,596],{},"Voorbeeld:",[67,598,599,602,605,608],{},[70,600,601],{},"Circuit 1: Verlichting gelijkvloers → Alle lichtpunten op het gelijkvloers krijgen \"1\".",[70,603,604],{},"Circuit 2: Stopcontacten woonkamer → Alle WK-stopcontacten krijgen \"2\".",[70,606,607],{},"Circuit 3: Stopcontacten keuken → Alle KE-stopcontacten krijgen \"3\".",[70,609,610],{},"Circuit 4: Apart oven → Eén stopcontact met \"4\".",[25,612,613,622],{},[16,614,615,617,618,621],{},[20,616,65],{}," De nummers moeten tussen éénlijnschema en situatieschema ",[20,619,620],{},"exact overeenkomen",". Inconsistenties zijn een van de meest voorkomende redenen voor opmerkingen bij de keuring.",[16,623,624,627],{},[20,625,626],{},"Documentatieplicht:"," Art. 9.1.2 Nr. 1 (éénlijnschema) en Art. 9.1.2 Nr. 2 (situatieschema\u002Flageplan).",[46,629],{},[49,631,633],{"id":632},"stap-5-legende-en-opschrift","Stap 5: Legende en opschrift",[16,635,636],{},"Vul uw plan aan met:",[67,638,639,645,651,657],{},[70,640,641,644],{},[20,642,643],{},"Legende"," met alle gebruikte symbolen en hun betekenis.",[70,646,647,650],{},[20,648,649],{},"Titelblok"," (cartouche) met: naam eigenaar, adres, datum, planmaker, schaal.",[70,652,653,656],{},[20,654,655],{},"Noordpijl"," (optioneel, maar nuttig).",[70,658,659,662],{},[20,660,661],{},"Verdiepingsaanduiding"," bij gebouwen met meerdere verdiepingen (één plan per verdieping).",[46,664],{},[49,666,668],{"id":667},"veelgemaakte-fouten","Veelgemaakte fouten",[99,670,671,684],{},[102,672,673],{},[105,674,675,678,681],{},[108,676,677],{},"Fout",[108,679,680],{},"Gevolg",[108,682,683],{},"Oplossing",[118,685,686,697,708,719,729,740,750],{},[105,687,688,691,694],{},[123,689,690],{},"Ontbrekende rookmelders",[123,692,693],{},"Keuring niet geslaagd",[123,695,696],{},"Min. 1 per verdieping in vluchtwegen (regionaal verschillend)",[105,698,699,702,705],{},[123,700,701],{},"Buitenstopcontact niet normconform",[123,703,704],{},"Opmerking, indien aanwezig maar niet conform",[123,706,707],{},"Indien geïnstalleerd: IP44, eigen 30mA differentieel. Een ontbrekend buitenstopcontact is geen reden voor afkeuring",[105,709,710,713,716],{},[123,711,712],{},"Ontbrekende opschriften \u002F circuitnummers",[123,714,715],{},"Opmerking",[123,717,718],{},"Elk onderdeel nummeren",[105,720,721,724,726],{},[123,722,723],{},"Verkeerde symbolen",[123,725,715],{},[123,727,728],{},"Alleen AREI Tabel 2.23 gebruiken",[105,730,731,734,737],{},[123,732,733],{},"Schakelaar aan verkeerde deurzijde",[123,735,736],{},"Onpraktisch (geen AREI-overtreding)",[123,738,739],{},"Openingsrichting controleren",[105,741,742,745,747],{},[123,743,744],{},"Badkamer-stopcontact in zone 0 of 1",[123,746,693],{},[123,748,749],{},"Stopcontacten pas vanaf zone 2 (alleen badkuip) of buiten de zones (douche) toegelaten (Art. 7.1.5.2c\u002Fd)",[105,751,752,755,757],{},[123,753,754],{},"Geen legende",[123,756,715],{},[123,758,759],{},"Symbooltabel bijvoegen",[46,761],{},[49,763,765],{"id":764},"checklist-voor-indiening","Checklist voor indiening",[67,767,770,780,786,792,798,804,810,816,822,828],{"className":768},[769],"contains-task-list",[70,771,774,779],{"className":772},[773],"task-list-item",[775,776],"input",{"disabled":777,"type":778},true,"checkbox"," Alle ruimtes gelabeld",[70,781,783,785],{"className":782},[773],[775,784],{"disabled":777,"type":778}," Alle stopcontacten, schakelaars, lichtpunten ingetekend",[70,787,789,791],{"className":788},[773],[775,790],{"disabled":777,"type":778}," Rookmelders in vluchtwegen (min. 1 per verdieping, regionaal verschillend)",[70,793,795,797],{"className":794},[773],[775,796],{"disabled":777,"type":778}," Buitenstopcontacten, indien aanwezig, normconform (IP44, eigen 30mA differentieel)",[70,799,801,803],{"className":800},[773],[775,802],{"disabled":777,"type":778}," Circuitnummers bij elk onderdeel",[70,805,807,809],{"className":806},[773],[775,808],{"disabled":777,"type":778}," Nummers komen overeen met éénlijnschema",[70,811,813,815],{"className":812},[773],[775,814],{"disabled":777,"type":778}," AREI-symbolen gebruikt (Tabel 2.23)",[70,817,819,821],{"className":818},[773],[775,820],{"disabled":777,"type":778}," Legende aanwezig",[70,823,825,827],{"className":824},[773],[775,826],{"disabled":777,"type":778}," Titelblok met naam, adres, datum",[70,829,831,833],{"className":830},[773],[775,832],{"disabled":777,"type":778}," Eén plan per verdieping",[46,835],{},[49,837,839],{"id":838},"gerelateerde-artikelen","Gerelateerde artikelen",[67,841,842,849,855],{},[70,843,844],{},[845,846,848],"a",{"href":847},"\u002Fblog\u002Fwat-is-eenlijnschema","Wat is een éénlijnschema?",[70,850,851],{},[845,852,854],{"href":853},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België",[70,856,857],{},[845,858,860],{"href":859},"\u002Fblog\u002Fverdeelkast-plannen-opbouw","Verdeelkast plannen: Opbouw en dimensionering",[46,862],{},[16,864,865],{},[34,866,867,868,871,872],{},"Met ",[20,869,870],{},"PlanElec"," maakt u uw situatieschema rechtstreeks vanuit het grondplan — ruimtes tekenen, apparaten slepen en neerzetten, AREI-symbolen worden automatisch gebruikt. ",[845,873,875],{"href":874},"\u002F","Nu gratis uitproberen →",{"title":877,"searchDepth":878,"depth":878,"links":879},"",2,[880,885,886,893,894,895,896,897],{"id":51,"depth":878,"text":52,"children":881},[882,884],{"id":56,"depth":883,"text":57},3,{"id":93,"depth":883,"text":94},{"id":212,"depth":878,"text":213},{"id":416,"depth":878,"text":417,"children":887},[888,889,890,891,892],{"id":423,"depth":883,"text":424},{"id":459,"depth":883,"text":460},{"id":484,"depth":883,"text":485},{"id":509,"depth":883,"text":510},{"id":540,"depth":883,"text":541},{"id":566,"depth":878,"text":567},{"id":632,"depth":878,"text":633},{"id":667,"depth":878,"text":668},{"id":764,"depth":878,"text":765},{"id":838,"depth":878,"text":839},"guide","2026-03-30","Volledige handleiding voor het maken van een AREI-conform situatieschema. Van de grondplanvoorbereiding via AREI-symbolen tot de afgewerkte tekening.","md","nl",{},"\u002Fblog\u002Fdraw-situation-plan.nl","8 min",12,{"title":6,"description":900},"situatieschema-tekenen-handleiding","blog\u002Fdraw-situation-plan.nl",[911,912,913,914,915,916,917],"situatieschema","AREI","symbolen","handleiding","tekenen","elektroplan","grondplan","xX_iD9De_y0ZulcG-M5dx4Pg6-zcCmVgi-8BfBtEtC8",{"id":920,"title":921,"articleId":922,"body":923,"category":1209,"date":1210,"description":1211,"extension":901,"lastUpdated":1210,"locale":902,"meta":1212,"navigation":777,"path":1213,"publishDate":1210,"readTime":1214,"refreshInterval":906,"seo":1215,"slug":1216,"stem":1217,"tags":1218,"__hash__":1225},"blog\u002Fblog\u002Fpreflex-vs-open-wiring.nl.md","Preflex vs. vrije bedrading: Welke kabelmethode voor uw project?","preflex-vs-open-wiring",{"type":9,"value":924,"toc":1200},[925,929,935,939,942,946,1061,1065,1085,1089,1109,1113,1132,1139,1143,1163,1165,1167,1187,1189],[12,926,928],{"id":927},"preflex-vs-vrije-bedrading-welke-methode-past-bij-uw-project","Preflex vs. vrije bedrading: Welke methode past bij uw project?",[16,930,931,934],{},[20,932,933],{},"Kort antwoord:"," Preflex is een voorgeconfectioneerde wachtbuis met reeds ingetrokken kabels — ideaal voor nieuwbouw, waar het direct in het beton wordt gegoten. Vrije bedrading (bijv. XVB opbouw of in kabelgoot) is beter geschikt voor renovaties, waar leidingen moeilijk achteraf te plaatsen zijn.",[49,936,938],{"id":937},"wat-is-preflex","Wat is Preflex?",[16,940,941],{},"Preflex is een flexibele golfbuis (wachtbuis), waarin in de fabriek de passende kabels al zijn ingetrokken. In België is deze methode bij nieuwbouw uiterst populair: de buizen worden tijdens de ruwbouwfase op de betonplaat of in de dekvloer gelegd en vervolgens ingegoten. Zo zijn de kabels volledig beschermd en later vervangbaar indien nodig.",[49,943,945],{"id":944},"vergelijking-preflex-safe-vs-gewone-preflex-vs-vrije-bedrading","Vergelijking: Preflex Safe vs. gewone Preflex vs. vrije bedrading",[99,947,948,964],{},[102,949,950],{},[105,951,952,955,958,961],{},[108,953,954],{},"Criterium",[108,956,957],{},"Preflex Safe",[108,959,960],{},"Gewone Preflex",[108,962,963],{},"Vrije bedrading (XVB)",[118,965,966,982,998,1014,1029,1045],{},[105,967,968,973,976,979],{},[123,969,970],{},[20,971,972],{},"Mantel",[123,974,975],{},"Halogeenvrij (LSOH)",[123,977,978],{},"Standaard PVC",[123,980,981],{},"Geen buis, kabel direct",[105,983,984,989,992,995],{},[123,985,986],{},[20,987,988],{},"CPR-brandklasse",[123,990,991],{},"Cca-s1,d1,a1 (kabel in buis)",[123,993,994],{},"Eca (kabel in buis; de CPR-klasse verwijst naar de kabel, niet naar de buis zelf)",[123,996,997],{},"XVB met CPR-markering Cca-s1,d2,a1 (bij nieuwbouwinstallaties in bepaalde plaatsingswijzen voorgeschreven; oudere voorraad kan nog als Eca geclassificeerd zijn)",[105,999,1000,1005,1008,1011],{},[123,1001,1002],{},[20,1003,1004],{},"Toepassing",[123,1006,1007],{},"Nieuwbouw, openbare gebouwen",[123,1009,1010],{},"Nieuwbouw woningbouw",[123,1012,1013],{},"Renovatie, opbouw",[105,1015,1016,1021,1024,1026],{},[123,1017,1018],{},[20,1019,1020],{},"Kabel vervangen mogelijk",[123,1022,1023],{},"Ja",[123,1025,1023],{},[123,1027,1028],{},"Nee (vast geïnstalleerd)",[105,1030,1031,1036,1039,1042],{},[123,1032,1033],{},[20,1034,1035],{},"Kosten",[123,1037,1038],{},"Hoogst",[123,1040,1041],{},"Gemiddeld",[123,1043,1044],{},"Laagst",[105,1046,1047,1052,1055,1058],{},[123,1048,1049],{},[20,1050,1051],{},"AREI-conform",[123,1053,1054],{},"Alle toepassingen",[123,1056,1057],{},"Woningbouw toegelaten",[123,1059,1060],{},"Alle toepassingen (mits juist kabeltype)",[49,1062,1064],{"id":1063},"voordelen-van-preflex","Voordelen van Preflex",[67,1066,1067,1073,1079],{},[70,1068,1069,1072],{},[20,1070,1071],{},"Nette installatie:"," Geen zichtbare kabels, alles ingewerkt of ingegoten.",[70,1074,1075,1078],{},[20,1076,1077],{},"Toekomstbestendig:"," Kabels kunnen later vervangen of toegevoegd worden zonder muren open te breken.",[70,1080,1081,1084],{},[20,1082,1083],{},"Bescherming:"," De buis beschermt tegen mechanische schade.",[49,1086,1088],{"id":1087},"nadelen-van-preflex","Nadelen van Preflex",[67,1090,1091,1097,1103],{},[70,1092,1093,1096],{},[20,1094,1095],{},"Duurder"," dan directe kabelinstallatie (materiaal + arbeidskosten).",[70,1098,1099,1102],{},[20,1100,1101],{},"Alleen bij nieuwbouw\u002Ftotaalrenovatie"," zinvol — bij eenvoudige renovatie nauwelijks achteraf plaatsbaar.",[70,1104,1105,1108],{},[20,1106,1107],{},"Buigstralen"," respecteren: te scherpe bochten bemoeilijken het latere naftrekken.",[49,1110,1112],{"id":1111},"wat-zegt-het-arei","Wat zegt het AREI?",[16,1114,1115,1116,1119,1120,1123,1124,1127,1128,1131],{},"Het AREI schrijft geen specifieke installatiemethode voor — beide zijn toegelaten. Bepalend is de ",[20,1117,1118],{},"brandveiligheidsklasse"," (CPR-verordening): Afzonderlijk geplaatste kabels moeten minstens ",[20,1121,1122],{},"Eca"," hebben (Art. 5.2.7.2). In ",[20,1125,1126],{},"bundels, holle wanden en bouwkundige holle ruimtes"," is minstens ",[20,1129,1130],{},"Cca"," voorgeschreven (Art. 5.2.7.3, Art. 4.3.3.5b). Let op: houtskeletwanden (bij renovaties veel voorkomend) gelden als bouwkundige holle ruimte!",[16,1133,1134,1135,1138],{},"De buis mag maximaal ",[20,1136,1137],{},"40%"," met kabels gevuld zijn (algemene installatieregel volgens de regels van het vak), zodat later naftrekken mogelijk blijft.",[49,1140,1142],{"id":1141},"wanneer-welke-methode","Wanneer welke methode?",[67,1144,1145,1151,1157],{},[70,1146,1147,1150],{},[20,1148,1149],{},"Nieuwbouw"," → Preflex (Safe voor hoogste brandveiligheid)",[70,1152,1153,1156],{},[20,1154,1155],{},"Renovatie"," → XVB-kabel in kabelgoot of opbouw",[70,1158,1159,1162],{},[20,1160,1161],{},"Gedeeltelijke renovatie"," → Combinatie mogelijk (nieuwe kringen in Preflex, bestaande behouden)",[46,1164],{},[49,1166,839],{"id":838},[67,1168,1169,1175,1181],{},[70,1170,1171],{},[845,1172,1174],{"href":1173},"\u002Fblog\u002Farei-2026-wijzigingen","Wat verandert er met het AREI 2026?",[70,1176,1177],{},[845,1178,1180],{"href":1179},"\u002Fblog\u002Fbadkamer-kabels-arei-zones","Badkamer-elektriciteit: Zones en kabeltypes",[70,1182,1183],{},[845,1184,1186],{"href":1185},"\u002Fblog\u002Foud-arei-part-8","Oudere installaties en AREI Part 8",[46,1188],{},[16,1190,1191],{},[34,1192,1193,1194,1196,1197],{},"Plan uw elektrische installatie normconform met ",[20,1195,870],{}," — of het nu nieuwbouw met Preflex is of een renovatie met vrije bedrading. Onze tool maakt automatisch het juiste éénlijnschema en situatieschema. ",[845,1198,1199],{"href":874},"Nu gratis starten →",{"title":877,"searchDepth":878,"depth":878,"links":1201},[1202,1203,1204,1205,1206,1207,1208],{"id":937,"depth":878,"text":938},{"id":944,"depth":878,"text":945},{"id":1063,"depth":878,"text":1064},{"id":1087,"depth":878,"text":1088},{"id":1111,"depth":878,"text":1112},{"id":1141,"depth":878,"text":1142},{"id":838,"depth":878,"text":839},"faq","2026-03-27","Vergelijking van Preflex-leidingen en vrije kabelinstallatie in België. Voordelen, nadelen en AREI-brandveiligheidsklassen in een overzicht.",{},"\u002Fblog\u002Fpreflex-vs-open-wiring.nl","3 min",{"title":921,"description":1211},"preflex-vs-vrije-bedrading","blog\u002Fpreflex-vs-open-wiring.nl",[1219,1220,1221,1222,912,1223,1224],"preflex","bedrading","nieuwbouw","renovatie","brandveiligheid","XVB","e3QQejGeOXOR4swzoaHbRX3YIZ75oRikmp_4yXSuvPU",{"id":1227,"title":1228,"articleId":1229,"body":1230,"category":1209,"date":1519,"description":1520,"extension":901,"lastUpdated":1519,"locale":902,"meta":1521,"navigation":777,"path":1522,"publishDate":1519,"readTime":1523,"refreshInterval":906,"seo":1524,"slug":1525,"stem":1526,"tags":1527,"__hash__":1534},"blog\u002Fblog\u002Frcd-type-a-vs-b.nl.md","Differentieel Type A vs. Type B: Wanneer heb ik welke nodig?","rcd-type-a-vs-b",{"type":9,"value":1231,"toc":1510},[1232,1235,1241,1245,1345,1349,1356,1376,1380,1383,1403,1407,1453,1457,1460,1480,1483,1487,1499,1501],[12,1233,1228],{"id":1234},"differentieel-type-a-vs-type-b-wanneer-heb-ik-welke-nodig",[16,1236,1237,1240],{},[20,1238,1239],{},"Het AREI schrijft minstens een differentieel (RCD) Type A voor als minimum."," Type B is vereist wanneer gelijkstroomfoutstromen kunnen optreden — typisch bij laadpalen zonder ingebouwde DC-foutstroomsensor of warmtepompen met frequentieomvormer. De keuze van het juiste RCD-type is cruciaal voor de veiligheid en de keuringsconformiteit.",[49,1242,1244],{"id":1243},"overzicht-van-alle-rcd-types","Overzicht van alle RCD-types",[99,1246,1247,1263],{},[102,1248,1249],{},[105,1250,1251,1254,1257,1260],{},[108,1252,1253],{},"Type",[108,1255,1256],{},"Detecteert",[108,1258,1259],{},"Toepassingsgebied",[108,1261,1262],{},"Prijs (ca.)",[118,1264,1265,1281,1297,1313,1329],{},[105,1266,1267,1272,1275,1278],{},[123,1268,1269],{},[20,1270,1271],{},"AC",[123,1273,1274],{},"Enkel zuivere wisselstroomfoutstromen",[123,1276,1277],{},"Verouderd, niet meer toegelaten voor nieuwe installaties",[123,1279,1280],{},"~€25–40",[105,1282,1283,1288,1291,1294],{},[123,1284,1285],{},[20,1286,1287],{},"A",[123,1289,1290],{},"Wissel- + pulserende gelijkstroomfoutstromen",[123,1292,1293],{},"Standaard voor huishouden",[123,1295,1296],{},"~€40–60",[105,1298,1299,1304,1307,1310],{},[123,1300,1301],{},[20,1302,1303],{},"A-SI",[123,1305,1306],{},"Zoals Type A, selectief (tijdvertraagd)",[123,1308,1309],{},"Hoofd-RCD (300 mA), vermijdt cascadeuitschakeling",[123,1311,1312],{},"~€80–120",[105,1314,1315,1320,1323,1326],{},[123,1316,1317],{},[20,1318,1319],{},"B",[123,1321,1322],{},"Alle foutstromen incl. gladde gelijkstroom",[123,1324,1325],{},"Laadpaal, warmtepomp met inverter",[123,1327,1328],{},"~€150–250",[105,1330,1331,1336,1339,1342],{},[123,1332,1333],{},[20,1334,1335],{},"F",[123,1337,1338],{},"Zoals A + frequentiegestuurde foutstromen",[123,1340,1341],{},"Frequentiegestuurde aandrijvingen (motoren)",[123,1343,1344],{},"~€100–180",[49,1346,1348],{"id":1347},"wanneer-is-type-b-vereist","Wanneer is Type B vereist?",[16,1350,1351,1352,1355],{},"Type B is nodig wanneer een toestel ",[20,1353,1354],{},"gladde gelijkstroomfoutstromen"," kan veroorzaken. Dit geldt vooral voor:",[67,1357,1358,1364,1370],{},[70,1359,1360,1363],{},[20,1361,1362],{},"Laadpaal (laadstation) zonder ingebouwde DC-foutstroomsensor:"," Eenvoudige laadstations zonder 6 mA DC-detectie hebben een Type B-RCD nodig",[70,1365,1366,1369],{},[20,1367,1368],{},"Warmtepomp met inverter (frequentieomvormer):"," De frequentieomvormer kan DC-foutstromen veroorzaken",[70,1371,1372,1375],{},[20,1373,1374],{},"PV-omvormer zonder transformator:"," Transformatorloze omvormers kunnen DC-componenten in het net invoeden",[49,1377,1379],{"id":1378},"wanneer-volstaat-type-a","Wanneer volstaat Type A?",[16,1381,1382],{},"Type A is voldoende voor:",[67,1384,1385,1391,1397],{},[70,1386,1387,1390],{},[20,1388,1389],{},"Laadpaal MET ingebouwde DC-foutstroomsensor (6 mA):"," De meeste moderne laadpalen (bv. met Type A-EV-modus) hebben een ingebouwde sensor die DC-foutstromen vanaf 6 mA detecteert en het laden onderbreekt",[70,1392,1393,1396],{},[20,1394,1395],{},"Gewone huishoudtoestellen:"," Wasmachine, vaatwasser, kookplaat, verlichting",[70,1398,1399,1402],{},[20,1400,1401],{},"Stopcontactkringen:"," Standaard 30 mA RCD Type A",[49,1404,1406],{"id":1405},"arei-vereisten","AREI-vereisten",[99,1408,1409,1419],{},[102,1410,1411],{},[105,1412,1413,1416],{},[108,1414,1415],{},"AREI Artikel",[108,1417,1418],{},"Vereiste",[118,1420,1421,1429,1437,1445],{},[105,1422,1423,1426],{},[123,1424,1425],{},"Art. 4.2.4.3",[123,1427,1428],{},"RCD is verplicht voor elke kring (TT-systeem)",[105,1430,1431,1434],{},[123,1432,1433],{},"Art. 4.2.4.3_b",[123,1435,1436],{},"Maximaal 8 eindkringen per 30 mA RCD",[105,1438,1439,1442],{},[123,1440,1441],{},"Art. 5.3.5.3_a",[123,1443,1444],{},"Differentieelstroombeveiliging in huishoudelijke installaties minstens Type A; aan het voedingspunt minstens 40 A nominale stroomsterkte",[105,1446,1447,1450],{},[123,1448,1449],{},"Art. 7.22",[123,1451,1452],{},"Laadpaal: Eigen kring met geschikte RCD",[49,1454,1456],{"id":1455},"selectiviteit-respecteren","Selectiviteit respecteren",[16,1458,1459],{},"Voor een correcte selectiviteit moet de installatie als volgt worden opgebouwd:",[581,1461,1462,1468,1474],{},[70,1463,1464,1467],{},[20,1465,1466],{},"Hoofd-RCD:"," 300 mA, Type A-SI (selectief, tijdvertraagd)",[70,1469,1470,1473],{},[20,1471,1472],{},"Groeps-RCD's:"," 30 mA, Type A (voor gewone kringen)",[70,1475,1476,1479],{},[20,1477,1478],{},"Speciale RCD:"," 30 mA, Type B (voor laadpaal\u002Fwarmtepomp, indien geen DC-sensor aanwezig)",[16,1481,1482],{},"Zo schakelt bij een fout enkel de verantwoordelijke groeps-RCD uit, niet de hoofd-RCD — de rest van de installatie blijft in werking.",[49,1484,1486],{"id":1485},"prijsverschil-en-aanbeveling","Prijsverschil en aanbeveling",[16,1488,1489,1490,1494,1495,1498],{},"Het prijsverschil tussen Type A (",[1491,1492,1493],"del",{},"€40–60) en Type B (","€150–250) is aanzienlijk. Controleer daarom altijd eerst of uw laadpaal of warmtepomp een ",[20,1496,1497],{},"ingebouwde DC-foutstroomsensor"," heeft. Zo ja, dan volstaat een goedkopere Type A-RCD. De documentatie van de fabrikant geeft hierover uitsluitsel.",[49,1500,839],{"id":838},[16,1502,1503,1504,1509],{},"Plan uw beveiligingstoestellen conform de normen met ",[845,1505,870],{"href":1506,"rel":1507},"https:\u002F\u002Fwww.planelec.be",[1508],"nofollow"," — automatische RCD-type-aanbeveling inbegrepen.",{"title":877,"searchDepth":878,"depth":878,"links":1511},[1512,1513,1514,1515,1516,1517,1518],{"id":1243,"depth":878,"text":1244},{"id":1347,"depth":878,"text":1348},{"id":1378,"depth":878,"text":1379},{"id":1405,"depth":878,"text":1406},{"id":1455,"depth":878,"text":1456},{"id":1485,"depth":878,"text":1486},{"id":838,"depth":878,"text":839},"2026-03-25","Vergelijking van alle RCD-types (AC, A, A-SI, B, F) voor Belgische elektro-installaties volgens het AREI.",{},"\u002Fblog\u002Frcd-type-a-vs-b.nl","5 min",{"title":1228,"description":1520},"differentieel-type-a-vs-type-b","blog\u002Frcd-type-a-vs-b.nl",[1528,1529,1530,1531,1532,1533],"differentieel","rcd","type-a","type-b","arei","laadpaal","iR0qsZS3FNBlq6efLstXv1hrxRsRt1RRp__gRaQBGAM",1775151655476]